Section 7 Specifications and Capacities
7/28/10
Model 2250 Air Drill Cart 167-033M
Great Plains Mfg., Inc.
Vansco Electronic Monitor Technical Specifications
Fan RPM
Fan RPM is displayed when the selector switch is set to FAN.
The RPM range is 0-9990 RPM with a resolution of 10 RPM.
The fan RPM is continuously monitored for alarm purposes.
The alarm trips when the fan speed falls below the user variable low alarm set point or goes above
the user variable high alarm set point
The factory programmed low alarm point is 3000 RPM. The user adjustable range is between 0 and
the high set point. Low alarm point should be set at 2000 RPM.
The factory programmed high alarm point is 6500 RPM. The user adjustable range is between 0 and
9900 RPM. Reset the high alarm point at 5000 RPM.
The factory programmed pulses per revolution is 1. Reset pulses per revolution to 3.
Response time to an alarm condition is 1 second maximum.
Shaft RPM
Two shaft speeds, Front and Rear are monitored. Shaft speeds are displayed when the rotary switch is set
to the appropriate position.
The operator may disable unwanted shaft inputs.
The input signal is from a reed switch.
All shaft speeds are continuously monitored for alarm purposes.
An alarm will be generated whenever there is more than 15 seconds between reed switch hits.
Shaft alarm generation will be delayed by 30 seconds if ground speed is below 2 MPH. This delay is
intended to reduce nuisance alarms when turning on headlands.
The monitors are factory programmed with the bins and shafts disabled.
Set both shafts for 2 pulses per revolution.
Bin Level Indication
Two bin levels are monitored; Front and Rear
The bins are pressurized to 20" - 30" H
2
0
The input signal is a Vansco 77000 series optical Type Full Bin Detector
To minimize nuisance alarms, there is a 15 second delay before the bin alarm is displayed
When a shaft input is disabled, the corresponding bin level input is also disabled.
The monitors are factory programmed with bins and shafts disabled.
Standard Parameter Settings for 2250 Air Drill Systems Monitor
Function
Display
Value
Fan Speed Pulses Per Revolution
PLSE
3
Fan Low Speed Alarm
FAnL
2000
Fan High Speed Alarm
FAnH
5000
Ground Speed Pulses Per Mile (average drills)
PLSE
34’ Drill 2213
45’ Drill 2900
Front Shaft Pulses Per Revolution
PLSE
2
Rear Shaft Pulses Per Revolution
PLSE
2
Flow or Blockage Module Complement (for drills without blockage sensing)
xx--
xx00
Flow or Blockage Module Type Value
tY--
tY00
Implement Width
Lnth
34’ Drill 34.0
45’ Drill 45.0
English or Metric Units
unit
Eng
NOTE: Monitor is shipped from the factory with all sensors disabled or set to null values. Correct values must be set on monitor
prior to initial use, based on actual unit width.