Inductor (optional equipment) – Great Plains 3P-FF900 Operator Manual User Manual
Page 31

12/8/2009
500-643M
29
Operating Instructions
Inductor (Optional Equipment)
The Inductor option is used to induct chemical into
the main sprayer tank so that the operator doesn’t
have to climb up the walk-board to do so.
To induct chemical into the tank refer to the follow-
ing instructions:
Refer to Figure 12
1.
Fill the main sprayer tank with the carrier
needed and transport the sprayer to the field
where the sprayer will be used.
2.
Make sure the boom section switches are all
off and operate the pump.
3.
Turn the agitation valve #1 to “AGITATION”,
the tank valve #2 to “MAIN TANK” and the op-
eration valve #3 to “SPRAY”. Be sure the
valve to the tank is open.
4.
Turn the product valve #4 from “OFF” to “IN-
DUCT”.
5.
Add chemical to inductor tank.
6.
Turn inductor valve #5 from “INDUCTOR
OFF” to “INDUCTOR ON”.
Figure 12
Product Valve and Inductor Valve