Using handwash tank, Agitation, Operating whirlfilter – Great Plains 3P-FF900 Operator Manual User Manual
Page 29: Transporting

12/8/2009
500-643M
27
Operating Instructions
Using Handwash Tank
In the event when an accident occurs and chemical is
spilled on your skin or in your eyes, use the Handwash
Tank to flush away the chemical.
1.
Open the tank valve and use the hose to direct the
clean water on all contaminated areas. Wash all ar-
eas of skin that has been contaminated with soap
and water. To flush your eyes, point the hose and
water stream upward while you lower your eye into
the stream of flowing water.
2.
Close the tank valve and refill the handwash tank
with fresh water when you are finished.
3.
Periodically refill the handwash tank with fresh wa-
ter. Always keep the handwash tank clean.
Agitation
Refer to Figure 10
To adjust the agitation, adjust the Agitation Valve shown.
Refer to the agitation gage to set a reference pressure
for the agitation.
Operating Whirlfilter
®
There is one Whirlfilters
®
filter on your Great Plains
Sprayer. The Whirlfilters
®
filters the chemical solution
being sprayed.
To clean-out the solution Whirlfilter
®
, proceed with the
following:
1.
Fill the sprayer tank with water and turn the pump
on.
2.
With the pump running, slowly open the clean-out
valve and allow the grit to flow out into a bucket.
Clean out the solution Whirlfilter
®
only when the
sprayer tank is filled with water and no chemical has
been added.
3.
Close the clean-out valve and turn off the pump.
4.
Dispose of the grit and water in the same manner
described on the manufacturer’s label of the latest
chemical used in the sprayer.
Transporting
1.
Park your sprayer in an open area where you will not
hit power lines, buildings, etc. when the boom is fold-
ed.
2.
Never allow riders when transporting the sprayer.
3.
When transporting your sprayer, be sure to watch
the height clearances of your folded boom to prevent
damage to the boom and possible injury.
Contact with electrical power lines can cause death by elec-
trocution.
4.
Do not exceed 20 mph transporting your sprayer.
5.
Do not transport sprayer while filled with chemical
mixture.
Figure 10
Agitation Valve
22934