Field operation, Auto-control spraying passes, Manual control spraying passes (2007-) – Great Plains 3P300 Operator Manual User Manual
Page 42

38
3P300 S/N HH1113+
Great Plains Manufacturing, Inc.
500-103M-A
09/14/2009
Field Operation
Auto-Control Spraying Passes
With maintenance up to date, Raven SCS 440 set up,
calibration complete, water material loaded, and agita-
tion adjusted; typical field operation includes these steps:
1.
Check that fill, drain and clean-out valves (
,
,
) are closed.
2.
and
: as adjusted
: to Front (SPRAY)
and
: closed
and
: open
3.
Line up at field edge.
Unfold booms.
4.
Set 3-point or elevator to desired canopy clearance.
Set elevator switch off, or circuit to neutral, to hold
height.
5.
Raven SCS 440:
FLOW CONTROL: switches as desired.
POWER: ON
MASTER: OFF
Boom sections: ON.
6.
Pump: on
7.
Raven MASTER: ON
As spray reaches nozzles, accelerate to spraying
speed.
8.
At pass end:
MASTER: OFF (pump may be left on)
Raise one or both boom sides as needed for turns.
9.
Lower boom(s).
MASTER: ON
10. Monitor the SCS 440 to confirm that desired rates
are achieved. Check sight gauge to confirm.
Manual Control Spraying Passes (2007-)
With maintenance up to date, calibration complete, water
material loaded, and agitation adjusted; typical field
operation includes these steps:
1.
Check that fill, drain and clean-out valves (
,
,
) are closed.
2.
and
as adjusted
front/spray
and
closed
and
open
3.
Line up at field edge.
Unfold booms.
4.
Set 3-point or elevator to desired canopy clearance.
Set elevator switch off, or circuit to neutral, to hold
height.
5.
Raven SCS 313:
POWER: ON
MASTER: OFF
Boom sections: ON.
6.
Pump: on
7.
Raven MASTER: ON
As spray reaches nozzles, accelerate to spraying
speed.
8.
At pass end:
MASTER: OFF (pump may be left on)
Raise one or both boom sides as needed for turns.
9.
Lower boom(s).
MASTER: ON
10. Monitor SCS 313 pressure reading, and monitor the
sight gauge to confirm that material is being con-
sumed at the expected rate.
6
7
8
1
2
3
4
5
9
10
6
7
8
1
2
3
4
5
9
10