beautypg.com

Great Plains PFH-20 Operator Manual User Manual

Page 24

background image

22

Section 4 Maintenance & Lubrication

PH-15, PH-20, PFH-15 and PFH-20 Coulter Command System 148-384M

6/21/2004

Great Plains Mfg., Inc.

Maintenance

The Coulter Command is relatively maintenance free.
The switches, sensors, and linkages should not need
any routine adjustment unless they are moved or
damaged.

Lubrication

Lubrication is required every 50 hours of operation.

Use a multipurpose spray club. Use as required.

Do not over lubricate.

Lubrication Symbols

As

Required

Seasonally

50

Lubrication is required

Lubrication is required every 10 hours of operation.

10

Depth Sensing Arm Wheel Pivot

Located on the depth sensing wheel Pivot Arm (2 Total)

Type of Lubrication: Multi-Purpose Lithium Base Grease

Quantity: Until grease begins to emerge

12405

12

Axle Bearings

Repack

Type of Lubrication: Wheel Bearing Grease

Quantity: Full Pack

12408

2 - 3 Years

Section 4

Maintenance & Lubrication