beautypg.com

Great Plains 3N-3020P Operator Manual User Manual

Page 57

background image

4/23/2010

196-248M

55

Maintenance and Lubrication

1.

Remove the retaining clip and pull pin. Do not
remove cotter pin.

18302

Retaining
clip

Shut off
pad

Sliding seed
tube

2.

Move meter cap to position seed tube over
shut off pad.

3.

Place pin in hole of meter cap and install re-
taining clip.

4.

Repeat steps 1 through 3 for each meter.

18303

Retaining
clip

Sliding
seed tube

NOTE: When pin with retaining clip is located
in the slot, sliding seed tube is open. When pin
with retaining clip is located in the hole, slid-
ing seed tube is closed.

Shutting Off Seed Flow
Refer to 46

To shut off seed flow, move front seed tubes back-
ward and back seed tubes forward. The following
instructions explain how to shut off seed flow to
each meter.

18290

Shut off

Shut off

Sliding seed
tubes

Refer to Figure 47

Refer to Figure 48

Figure 46

Figure 47

Figure 48