11
Section 2 Fertilizer Option Assembly
2/20/2006
PFH-15 and PFH-20 Precision Fertilizer Hitch 148-365Q
Great Plains Mfg., Inc.
Installing Strainer
Refer to Figure 2-3.
1.
On left side of hitch tongue, clamp valve mount plates
(1) around front coulter toolbar using 5/16-inch bolts
(2), washers and nylock nuts.
2.
Mount 1 1/2-inch valve (3) on valve mount plates.
3.
Using 1 1/2-inch threaded adaptor (4), connect strain-
er (5) to 1 1/2-inch valve.
4.
Install 1 1/2-inch elbow (6) in front of strainer.
5.
Use hose (7) and worm clamps to connect strainer to
pump inlet. (Inlet is on the bottom side of the pump.)
6.
Connect 1 1/2-inch valve to tanks using 1 1/2-inch
threaded/hose barb adaptor (8).
Figure 2-3
Assemble Strainer
18057
NOTE: Use pipe sealant, Rectorseal 21 Blk Thread Seal-
ant (Great Plains Part Number 890-310C), on all threaded
joints.