Intake – Wheatheart Galvanized Utility Auger User Manual
Page 15

W
HEATHEART
- G
RAIN
A
UGERS
3. A
SSEMBLY
U
TILITY
3.4. I
NTAKE
30644 R1
15
Figure 3.4
3.4. INTAKE
Note:
To replace intake assembly with hopper assembly or to install hopper assembly,
see Section 3.8.
1. Attach intake flighting to the flighting of galvanized tube. Ensure that the 2
flightings overlap. Use two 7/16” x 2-1/4” (for 8") or two 1/2” x 2-3/4” (for 10")
bolts and locknuts and tighten securely.
2. Place intake assembly over intake flighting, ensuring that the stub shaft is
properly seated in the bushing.
3. Attach intake to the clamp-on angle flange of galvanized tube with four
7/16” x 1" bolts and locknuts.
Figure 3.5