ClearOne RAV 900 User Manual
Page 54
Appendix — Serial Commands
103
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendix — Serial Commands
102
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
LVLREPORTEN - Level Report Enable
Enables level reporting for the unit.
ARGUMENT DETAILS
Name
Type
Size
Values
Units
Value
Unsigned Integer
4
0 = Turn off reporting but leave current list
1 = Turn on reporting
2 = Turn off reporting and clear the list
(Null to query in text)
BINARY FORM DETAILS
COMMAND ID:
16
NUMBER OF ARGUMENTS:
1
ARGUMENT FORM:
TEXT FORM DETAILS
COMMAND FORM:
DEVICE LVLREPORTEN [Value]
MANUFACTURER - Manufacturer Identification Label
This selects/reports the manufacturer identification label of the specific channel.
ARGUMENT DETAILS
Name
Type
Size
Values
Units
Channel
Channel
1
See Group and Channels
Group
Group
1
2, 3, 7(O, M, L)
Reserved Unsigned Integer
2
0
Label
String
32
1 - 32 characters
CLEAR = clear the label
(Null to query in text)
BINARY FORM DETAILS
COMMAND ID:
81
NUMBER OF ARGUMENTS:
9
ARGUMENT FORM:
TEXT FORM DETAILS
COMMAND FORM:
DEVICE MANUFACTURER
LVL - Level
This command reports the level of a channel. This command is read-only.
ARGUMENT DETAILS
Name
Type
Size
Values
Units
Channel
Channel
1
See Group and Channels
Group
Group
1
2, 3, 7, 16, 17(O, M, L, T, R)
Position
Meter Type
2
See MeterTypeDefinitions
Value
Signed Float
4
-99.99 - 99.99
DB
(Sent with Null in text,
Value returned)
BINARY FORM DETAILS
COMMAND ID:
9
NUMBER OF ARGUMENTS:
2
ARGUMENT FORM:
TEXT FORM DETAILS
COMMAND FORM:
DEVICE LVL
LVLREPORT - Level Report
This command selects/reports the status of level reporting for the specified channel.
ARGUMENT DETAILS
Name
Type
Size
Values
Units
Channel
Channel
1
See Group and Channels
Group
Group
1
2, 3, 7, 16, 17 (O, M, L, T, R)
Position
Meter Type
2
See MeterTypeDefinitions
Value
Unsigned Integer
4
0 = Off (Delete from list being reported)
1 = On (Add to list being reported)
2 = Toggle(Null to query in text)
BINARY FORM DETAILS
COMMAND ID:
10
NUMBER OF ARGUMENTS:
2
ARGUMENT FORM:
TEXT FORM DETAILS
COMMAND FORM:
DEVICE LVLREPORT