Pan6400 command set, Sample commands, Commands from pc – ClearOne RS-232 User Manual
Page 12: Commands from mu5066, Table 4-2, Table 4-3, Table 4-4
NetStreams PAN6400 RS-232 Integration Guide
4-2
PN: 020001
All specifications subject to change without notification. All rights reserved. Copyright © 2006 NetStreams
Main +1 512.977-9393 / fax +1 512.977.9398 / Toll Free Technical Support +1 866-353-3496
3600 W. Parmer Lane, Suite 100; Austin, TX 78727 /
www.netstreams.com.
PAN6400 Command Set
When programming IR for the PAN6400, use the following RS-232 commands. If
connected to an MU5066ADC, refer to the Musica MU5066 Integration & Design
Guide on the NetStreams web site for the MU5066 command set.
Sample Commands
Table 4-2
Commands from PC
Command
Sub_Command
Parameters
Send Command
Respond
Note
Attribute
Description
Code
Zone(Z)
Value name
(Initial)
Value
Dir(D)
State
Chang
Nudge
State
Version
Version(Ver)
51
0
---
51
---
State/51/Z
---
---
State/51/0/V50901
Zone: 0 (Main for version)
Initialize Commands: State/51/V/I
Chang
Source(Src)
Source(Src)
61
0-6
Source No. (S)
0,1-4,N
0,1
State/61/Z
Chang/61/Z/S Nudge/61/Z/D
State/61/Z/S
Source: 0 (Off)
N (No change, just power on)
IRFrequency (IRFreq) IRFrequency
(IRFreq)
62
---
Select Output. (O)
Output No. (N)
IR Frequency
(KHz).(I)
R,S
(0,1-6)(0,1-4)
0,1
0,1
State/62/O/N Chang/62/O/N/
I
Nudge/62/O/N/D State/62/O/N/38(56)
Source: 0 (All)
R (Room IR), S (Source IR)
IR: 0 (38KHz), 1 (56 KHz)
Nudge
Status
Front Panel
(Panel)
71
---
On/Off (O)
0,1
0,1
State/71
Chang/71/O
Nudge/71/D
State/71/O
---
Press
51
---
S, K
S (0~4,
10~16),
K (0~9)
S (0:all source, 1~4:S1~S4, 10: all
zone, 11~16:Z1~Z6)
K (0~9:Remote Button Number)
Command
Sub_Command
Parameters
Send
Command
Respond
Note
Attribute
Description
Code
Zone(Z)
Event
Source
Source Settings
51
---
0 : disable, 1 : enable Event/51/E
Event/51/Z1/Z2/Z3/Z4/Z5/Z6 Z1~6 : Source No. for each Zone
Table 4-3
Commands from MU5066
Command
Sub_Command
Received Command
Respond
Note
Attribute
Description
Code
Event
Source
Source Settings
11
Event/11/Z1/Z2/Z3/Z4/Z5/Z6
---
Z1~6 : Source No. for each Zone, Source No. : 0(Off)
Event Press
---
---
---
EventPress/S/K/Z
---
S : Source Number
K: Key Number
Z: Zone Number
Table 4-4
Sample Commands
Command
State
Example
Response from Pan6400
Zone Status
State/61/Z
(Z=Zone) [0,1-6]
State/61/2
(Status of Zone 2)
State/61/2/3
Change Source
Chang/61/Z/S
(Z=Zone, S=Source) [0,1-4]
Chang/61/3/2
(Switch Source 2 to Zone 3)
State/61/3/2*
(*This command will follow
unsolicited data if enabled.)
Nudge Source
Nudge/61/Z/D
(Z=Zone, D=Direction)
[0,1-4/ 0 down -1 up]
Nudge/61/3/1
(Switch to next source in Zone 3)
State/61/3/3*
(* This command will follow
unsolicited data if enabled.)