Operation


COLORado™ 1-Tri IP User Manual Rev. 01c

-9-

4. Operation

Control Panel

Description

Button

Function

Exits from the current menu or
function

Enables the currently displayed
menu or sets the currently
selected value in to the current
function

Navigates upwards through the
menu list and increases the
numeric value when in a function

Navigates downwards through
the menu list and decreases the
numeric value when in a function

Control Options

You can set the COLORado™ 1-Tri IP start address in the 001~512 DMX range. This
allows for the control of up to 51 fixtures in the 10-channel TOUR personality. In
addition, the ID address system allows you to assign up to 66 fixtures within the same
DMX address, thus multiplying the number of fixtures you can control within a single
universe. You can access the fixture’s ID address system from channel 10 when in the
TOUR personality.

When programming live performances as well as cues that need to trigger on
demand or on a time line, program no more than 10 fixtures on ID addressing per
DMX channel. This is to remain within a one-second execution time.

Programming

Carry out all the programming procedures indicated below from the control panel. Refer
to the Menu Map on page 14 to learn how the menu options relate to each other.

To go to an option, press

repeatedly until the option shows on the display.

To select an option value, press or until you see the desired value and
press to accept it.

To exit to the previous menu level, press

.

DMX Personality

This setting allows the user to choose a particular DMX personality.

1) Go to PERS.

2) Select the desired personality (TOUR, ARC1, AR1 + D, AR1 + S, or HSV).

3) Make sure that the starting addresses on the various fixtures do not overlap due to

the new personality setting. See the DMX Values section.

DMX Control

Without ID

Addressing

In this mode, each unit will respond to a unique starting address from the DMX
controller. All units with the same starting address will respond in unison.

1) Select the TOUR personality as shown in DMX Personality.

2) Set the running mode:

a) Go to RUN.

b) Select DMX.

3) Set the starting address:

a) Go to DMX.

b) Select the starting address (001~512).

4) Deactivate ID Addressing on each fixture:

a) Go to SET > ID.

b) Select OFF.

Make sure to deactivate ID Addressing in each fixture when using the TOUR
personality. Otherwise, unintended results may occur if channel 10 is not set to
“0”.



Continues on the next page