beautypg.com

LaMotte PERACETIC ACID TEST KIT User Manual

Page 2

background image

PERACETIC ACID
NOTE: This method may be used to test low to high con cen tra tion of peracetic
acid. Choose the pro ce dure that is most appropriate for the sample being tested.

1 drop = 15 ppm

1.

Fill test tube (0715) to 10 mL line with sample water.

2.

Add 10 drops of *Sulfuric Acid, 1:1 (6141WT). Swirl to mix. Make sure
solution is thoroughly mixed.

3.

Add 1 drop of Ferroin Indicator (6410). Swirl to mix. Make sure solution is
thoroughly mixed.

4.

Add 1 drop of *Potassium Iodide 20% Solution (6521). Swirl to mix. Make
sure solution is thorougly mixed. Solution will turn a cloudy brown if
peracetic acid is present.

5.

While gently swirling tube, add Peracetic Acid Titrant (S-6155), one drop
at a time until brown color changes to a clear, pale orange-pink which
persists for 20 seconds. Make sure solution is thoroughly mixed. Count the
number of drops added.

6.

Multiply the number of drops used in Step 5 by 15 (fifteen). Record as ppm
Peracetic Acid.
For example:
10 drops x 15 = 150 ppm Peracetic Acid

1 drop = 6ppm
Fill the test tube to the 25 mL line. Follow the test procedure and use 25 drops
of *Sulfuric Acid, 1:1 (6141WT), 3 drops of Ferroin Indicator (6410) and 3
drops of *Potassium Iodide 20% Solution (6521). In Step 6 multiply the number
of drops used by 6 (six). Record as ppm Peracetic Acid.

For example:
10 drops x 6 = 60 ppm Peracetic Acid

1 drop = 300 ppm
For higher concentrations of peracetic acid use the 0.5 mL pipet (0353) to add
0.5 mL of the sample to the test tube (0715). Fill the tube to the 10 mL line with
hydrogen peroxide/peracetic acid-free water. Follow Steps 2 - 5. In Step 6
multiply the number of drops used by 300 (three hundred). Record as ppm
Peracetic Acid

For example:
10 drops X 300 = 3000 ppm Peracetic Acid

LaMOTTE COM PANY

Helping Peo ple Solve An a lyt i cal Challenges

®