Off/fld* off/chp, Off del time, Off/ xxx – Exide Technologies SCR100 Charger User Manual
Page 18: Off col* time, Off rfr* time
Instr. 4770-65-95005-00 Page 14
9.0 SCR100 STANDARD CHARGER OPERATION
LED
DISPLAY
DESCRIPTION
(NONE)
OFF/Fld*
OFF/CHP*
PLUG IN BATTERY TO COMMENCE CHARGING
CHARGER SET FOR FLOODED BATTERIES.
CHARGER SET FOR SEALED CHAMPION®
BATTERIES.
DELAY (Orange), dEL, then
delay time remaining in Hours.
minutes
OFF
dEL
time
DELAY MODE, PRESS “START” BUTTON TO
OVERRIDE. (Section 9.1.1, page 15)
CHARGING (Orange)
XXX*
SMART START (Section 9.1.2, page 15)
(DISPLAY OF FINISH RATE CURRENT)
CHARGING (Orange)
XXX
HIGH RATE CHARGING
(DISPLAY OF CHARGE CURRENT)
80% CHARGED (Yellow)
XXX
FINISH RATE CHARGING
(DISPLAY OF FINISH RATE CURRENT)
OPC
OPPORTUNITY CHARGING CYCLE
WHEN CHARGER IS IN OPC MODE IT WILL ALWAYS
INDICATE OPC IN ADDITION TO STANDARD INDICATION.
FAULT (Red)
OFF
CHARGE CYCLE WAS INTERRUPTED BY
PRESSING “STOP” BUTTON BEFORE
UNPLUGGING THE BATTERY
FAULT (Red)
OFF/
XXX
FAULT CONDITION EXISTS. UNPLUG THE
BATTERY AND GO TO APPENDIX A FOR
DETAILS. OTHER INDICATION DISPLAYED (i.e.
FAC, Fdc, Lo, HI, etc.)
CHARGE COMPLETE (Green)
flashing, remaining cooldown time
displayed in Hours.minutes
OFF
CoL*
time
CHARGING IS COMPLETE. ONCE COOLDOWN
TIME IS FINISHED, UNPLUG THE BATTERY.
CHARGE COMPLETE (Green)
on (not flashing), remaining
refreshing time displayed in
0
Hours. minutes
OFF
rFr*
time
BATTERY CAN BE UNPLUGGED AND USED.
EQUALIZE (Orange)
XXX
PRESS “EQUALIZE” BUTTON TO EQUALIZE THE
BATTERY. PRESS AGAIN TO CANCEL.
(DISPLAY OF CHARGE CURRENT)
∗∗
THESE DISPLAYS OR OPTIONS ARE AVAILABLE ONLY ON Z MODEL CHARGERS OR REPLACEMENT BOARDS