Weller WHA 30 P User Manual
Page 12

Page
12
COOPER TOOLS GmbH
Carl-Benz-Str. 2 74354 Besigheim 3
Germany Tel: 07143-580-0, Fax: 07143-580-108
9. Error messages
Error
Description
Rectification
ERROR 75
Offset entry on heating element change incorrect Repeat process
ERROR 76
Heating element faulty
Replace heating element
ERROR 110
WHP3000 housing temperature exceeded
Allow to cool down
REMOTE
Input inhibited (can only be operated using PC)
Operate using PC
LOCKED
WHA locked (lock function)
Unlock WHA
TOOL STAND
AKT30 Stand (or WBH3000 Proximity Sensor)
Connect to socket (17)
not connected
10. Accessories
For nozzle range, see p. 13
005 31 190 99
External Sensor Type K 0.5mm
005 87 367 80
Manual Control Console
005 15 048 99
Multiple stand for hot gas nozzles
005 31 191 99
Interface cable
005 33 162 99
WBH3000 Circuit Board Holder
005 33 163 99
WBH3000S Circuit Board Holder with WHA3000 Stand
005 33 386 99
WHP3000 Bottom heater
11. Items supplied
Controller with hand-piece
AKT30 Safety Stand
Nozzle Change Tool
Coded Plug
Tool Kit (2,5 mm Hex Wrench w / 2 3 mm Ø x 6 mm L screws provided)
Hot Air Nozzle
Main Power Cord 120VAC
Foot switch
Product CD-Rom (Operating Instruction incl. WHA Control Software)
Subject to technical change without notice!