beautypg.com

Final finishing hearth, Gas specifications, Certified to – Vermont Casting BHDR36 User Manual

Page 6: Gas inlet & manifold pressures

background image

- 6 -

Do not use this fireplace if any part of it has
been under water. Immediately call a qualified
service technician to inspect the fireplace
and replace any part of the control which has
been under water.

Cold climate installation recommendation:
When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory that the outer walls be insulated
to conform to applicable insulation codes.

Non-combustible materials such as brick and tile can be
extended over the outer face of the unit

(Do not cover

louvres or glass door). If a Trim Kit is going to be installed,
brick and tile will have to be installed flush with the side of
this appliance.

FINAL FINISHING

HEARTH

A hearth is not mandatory but it is recommended for
aesthetic purposes. We recommend a non-combustible
hearth which does not obstruct louvre opening.

GAS SPECIFICATIONS

MAX.

MIN.

INPUT

INPUT

MODEL

FUEL

GAS CONTROL B.T.U.H

B.T.U.H.

BHDR36 RN

Natural Gas

Millivolt Hi/Lo

18,000

12,600

BHDR36 RP

Propane Gas

Millivolt Hi/Lo

18,000

13,500

CERTIFIED TO

ANSI Z21.88a-1998 / CSA 2.33a-M98

Vented Gas Fireplace Heaters

The installation of your Majestic Fireplace
must conform with local codes, or in the
absence of local codes, with National Fuel
Gas Code, ANSI Z223.1 latest edition, or CAN
1 B1-149.1 and .2 Installation Code.
(EXCEPTION: Do not derate this appliance
for altitude. Maintain the manifold pressure
at 3.5 inches W.C. for Natural Gas and 10
inches W.C. for LP gas.)

GAS INLET & MANIFOLD PRESSURES

Input Minimum

Input Maximum

Manifold Pressure

NATURAL

LP (Propane)

11" wc

13" wc

10" wc

4.5" wc

7" wc

3.5" wc