P20 PUMP OPERATION / MAINTENANCE MANUAL
5
START-UP
Open the fluid suction (IN) line valve, if necessary
Open the fluid discharge (OUT) line valve, if necessary
Pump air supply pressure should be regulated
Operate pump at 20 psig initially to prime pump
Increase pressure to attain desired flow, (not to exceed 80 psig)
If the pump fails to start, refer to the troubleshooting section or contact Trebor for
further assistance.
ATTENTION: Prolonged periods (>5 minutes) of running without fluid can damage critical
internal pump parts.
CAUTION: When handling potentially dangerous fluids under pressure, the pump
and its fittings should be placed in an enclosure away from operators.
5.1 PERFORMANCE CHARTS
Pumping capacity is a function of air supply pressure and volume, suction head, suction
line restrictions, discharge head, discharge line restriction, and fluid specific gravity and
viscosity.
Air Supply
Pressure
(PSIG)
Discharge
Fluid
Pressure
(PSIG)
Flow
(LPM)
Cycles
Per
Minute
Displacement
cc Per
Cycle
Air
Consumption
(CFM)
20
0
14
100
140
4.6
20
10
11
100
110
40
0
18.5
180
103
6.0
40
20
12.5
104
125
60
0
20
210
95
7.0
60
30
15
110
137
80
0
21
218
97
8.0
80
40
16
132
121
Table 5-1: Performance Chart
NOTE: Test information is based on specific conditions and limited sampling. Use for
general reference only. This information is preliminary and may be changed at a future
date.