TROUBLESHOOTING
Pump Will Not Start, Fails to Operate
Cause:
Solution:
Insufficient air pressure
Increase regulated supply pressure or check control
valves for proper operation.
Rotate PC7 speed control screw CW until it stops. Then
readjust for correct speed (if applicable).
Debris in shuttle valve
Inspect/clean control valve assembly.
PC7 (if applicable)
Refer to PC7 Manual
Bubbles in Fluid Discharge
Cause:
Solution:
Inlet line fittings not tight
Check and tighten all fittings on the suction line feeding
the pump.
Flow too high
Under high flow conditions some fluids can cavitate
releasing dissolved air bubbles.
Diaphragm failure due to puncture
Contact Trebor Customer service for additional service
recommendations. Replace pump.
Fluid Leaks
Cause:
Solution:
Weld failure of fluid pump
Replace pump (Non Serviceable)
Fluid leaking from suction or discharge
connections
Inspect tubing and tighten fluid fittings.
Erratic Cycling
Cause:
Solution:
Debris in shuttle valve
Inspect/clean control valve assembly.
PC7 (if applicable)
Refer to PC7 Manual