3 pc15cp utilities / hook-up – Trebor PC15CP User Manual
Page 4

PAGE 4
PC15CP PUMP CONTROLLER OPERATION / MAINTENANCE MANUAL
1.3 PC15CP UTILITIES / HOOK-UP
Utility
Pump
Air Inlet:
1/4” Diameter (6mm) supply tube.
Air Supply:
80±5 PSIG (.55±.03 MPa), clean dry air or inert gas
Power
24VDC - 500mA
Controller Weight:
4.4 lbs (2.0 Kg)
ATTENTION: Air supplied to the PC15CP pump controller must be regulated to 80±5
PSIG. A secondary regulator controls pump air supply pressure.
Air supply connections between the pump and the pump controller are required.
NOTE:
3/8” tubing or larger is required for distances exceeding 3 meters between the
pump and the pump controller.
24VDC is required to operate the pump controller.
o Terminal blocks are insulation displacement type. Insert 18 gage wires into the
indicated location and push down lever to complete connection, see Figure .
NOTE: Follow local wiring codes and applicable wiring standards to insure proper power
and over-current protection.
Figure 2: 24VDC Connection