PC15CP PUMP CONTROLLER OPERATION / MAINTENANCE MANUAL
PAGE 11
5
TROUBLESHOOTING
SYMPTOMS
SOLUTIONS
Pump turns on when on/off switch is
activated, but the pump is running slow
Increase cycle rate setting: maximum of
375.
Pump flow does not increase with cycle
rate
Confirm regulated air supply pressure at
50-80 psig.
Increase pump discharge pressures if
discharge pressure is not surging!
Reduce inlet suction (Lift) requirements.
Pump is surging (discharge pressure
variation >4 psig)
Initiate controller calibration to reduce
pulsation. Contact Trebor
Reduce inlet suction requirements.
Increase cycle rate.
Controller display does not turn on
Check power supply voltage >19VDC.
Pump will not run
Check pump regulator pressure is above
15 psig.
Check controller air supply pressure <>
50-80 psig.
Check if remote operation enabled.
Pump will not prime
Increase cycle rate.
Check controller supply pressure is >50
PSIG.