1pc15cp installation – Trebor PC15CP User Manual
Page 3

PC15CP PUMP CONTROLLER OPERATION / MAINTENANCE MANUAL
PAGE 3
1
PC15CP INSTALLATION
1.1 PC15CP OVERVIEW
The PC15CP Pump Controller is designed to operate Trebor’s Purus CP pump. Cross-
phase timing results in overlapping pump strokes which produces a near pulse-less pump
output.
Note: Attach the included muffler prior to installation.
1.2 PC15CP INSTALLATION
The PC15CP pump controller can be installer in any orientation. Pump controller mounts
using two ¼” (6mm) bolts and should be mounted above the level of the fluid feeding the
pump. Allow clearance for tubing connectors.
Figure 1: Dimension (mm / [in])
Controller Air Supply
Connection (50-80 PSIG)
Pump Air Supply
Connection
Remote Capable
Exhaust Muffler
Pump Air Supply
Regulator
Air Flow Control
Valves