Relative light output vs temp (high mode), Relative input power vs temp (high mode) – TERRALUX MR16C User Manual
Page 3

www.terraluxillumination.com
TerraLUX TRK-R16 Product Specification (11/18/2013)
Subject to change without notice
3
LEDSense® OPERATION, THERMAL DERATING, & LUMEN MAINTENANCE
The TRK-R16 employs TerraLUX’s patented LEDSense® Thermal Management Technology to automatically provide max-
imum light output in various fixtures and operating conditions while assuring long-term lumen maintenance. LED-
Sense® regularly measures the operating temperature and ensures compliance with a pre-programmed temperature
and drive-current profile. This profile is based on the LED manufacturer’s LM-80 data report and minimum L70/60,000
hour lumen maintenance curves. LEDSense® is always active, and will compensate for variation in thermal conditions
due to heatsinking, ambient air, module positioning, or any other variable that affects the operating temperature. The
Thermal De-rating curve below identifies the relative light output that can be expected under various thermal condi-
tions. The LEDSense® Power Curve identifies the reduction in input power over temperature. .
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
25
35
45
55
65
75
R
e
la
ti
ve
L
ig
ht
O
ut
pu
t
Ambient temp. [°C]
Relative Light Output vs Temp (high mode)
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
25
35
45
55
65
75
R
e
la
ti
ve
I
np
ut
P
ow
e
r
Ambient temp. [°C]
Relative Input Power vs Temp (high mode)