TERRALUX SR8 Install User Manual
TERRALUX Lighting

TerraLUX Inc.
Document P/N 025000085B
1-866-498-1564
www.terralux.com
MODELS: TLM-D08A-A12XXR
& TLM-D08A-B12XXR
ROUND LED RETROFIT KIT INSTALLATION
INSTRUCTIONS
WARNING - RISK OF FIRE OR ELECTRIC SHOCK. LED RETROFIT KIT INSTALLATION 
REQUIRES KNOWLEDGE OF ELECTRICAL SYSTEMS. IF NOT QUALIFIED, DO NOT 
ATTEMPT INSTALLATION. CONTACT A QUALIFIED ELECTRICIAN. 
WARNING - RISK OF FIRE OR ELECTRIC SHOCK. INSTALL THIS KIT ONLY IN 
LUMINAIRES THAT HAVE CONSTRUCTION FEATURES AND DIMENSIONS SHOWN IN 
THE DRAWINGS “MIN. LAMP COMPARTMENT VOLUME 2200cm
3
(134 in
3
)
WARNING
– RISK OF FIRE OR ELECTRIC SHOCK. LUMINAIRE WIRING AND
ELECTRICAL PARTS MAY BE DAMAGED WHEN DRILLING FOR THE INSTALLATION OF 
THIS LED RETROFIT KIT. CHECK ENCLOSED WIRING AND COMPONENTS. 
WARNING
– TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING
TO EDGES OF SHEET METAL OR SHARP OBJECTS
DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRING OR 
ELECTRICAL COMPONENTS DURING KIT INSTALLATION. 
SUITABLE FOR DAMP LOCATION.
CNL REQUIREMENT
– THIS MODULE HAS AN OUTPUT RATED AT 46VDC. THIS
OUTPUT COMPLIES WITH THE DEFINITION OF CLASS 2 PER THE CANADIAN 
ELECTRICAL CODE. THIS OUTPUT CANNOT BE ACCESSIBLE BASED ON MAXIMUM 
VOLTAGE RESTRICTIONS FOR CLASS 2 CIRCUITS IN THE CANADIAN ELECTRICAL 
CODE. THE MODULE HAS ACCESSIBLE LED ARRAYS. THE LED ARRAYS OF THIS 
MODULE AT THE END PRODUCT SHOULD BE IN COMPLIANCE WITH THIS 
ACCESSIBILITY REQUIREMENT, EITHER BASED ON DESIGN OR BASED ON 
MANUFACTURERS SPECIFICATIONS FOR IT’S USE IN RESTRICTED ACCESS AREAS. 
 
THIS RETROFIT KIT IS INTENDED FOR INSTALLATION IN THE FOLLOWING TYPES OF LUMINAIRES: 
INDOOR/OUTDOOR WALL SCONCE (INCANDESCENT OR BALLASTED FLUORESCENT)
INDOOR/OUTDOOR SURFACE MOUNTED CEILING FIXTURES(INCANDESCENT OR BALLASTED 
FLUORESCENT) 
INDOOR/OUTDOOR PENDANT MOUNTED LIGHT FIXTURES(INCANDESCENT OR BALLASTED 
FLUORESCENT) 
 
INCLUDED COMPONENTS 
(1) RETROFIT KIT, MODELS TLM-D08A-A12XXR and TLM-D08A-B12XXR, INCLUDE:
o
(1) WIRE HARNESS (1-WHITE,1-BLACK OR BLUE, 1-GREEN WIRE AND PLUG)
o
(1) ROUND LED MOUNTING PLATE
o
(1) LED DRIVER MODULE WITH SMALL CONNECTOR (8-WHITE WIRES)
(3) WIRE NUTS
(2) #8-32 x 1-1/4 IN. MACHINE SCREWS
(1) RUBBER GROMMET
(1) MOIST TOWELETTE
(1) 1/8IN x 1/8IN x 1/2IN STAMPED HICKEY SPACER
(1) 1/8-27 X 1/2IN THREADED NIPPLE
(2) 1/8-27 IPS HEX NUTS
 
 
USER REQUIRED TOOLS 
#2 PHILLIPS SCREW DRIVER OR STRAIGHT BLADE
1/2in OPEN END BOX WRENCH OR PLIERS
DRILL WITH 3/8-INCH DIAMETER DRILL BIT
INSTALLATION STEPS (SURFACE MOUNT FIXTURE)
1.
SHUT OFF POWER TO LIGHT FIXTURE AT THE BREAKER
2.
REMOVE DIFFUSER/GLOBE FROM FIXTURE TO BE RETROFITTED, RETAIN HARDWARE.
3.
DISCONNECT/REMOVE BULB(S) FROM FIXTURE. DISPOSE OF OR RECYCLE PROPERLY.
4.
LOOSEN THE SCREWS THAT SECURE THE FIXTURE TO THE JUNCTION BOX (DO NOT REMOVE 
SCREWS). IF THE FIXTURE IS ALSO SECURED BY A THREADED MOUNTING TUBE, REMOVE THE IPS 
NUT IF NECESSARY. 
5.
SEPARATE FIXTURE FROM JUNCTION BOX TO EXPOSE FIXTURE WIRING.
6.
DISCONNECT FIXTURE MAINS WIRING FROM JUNCTION BOX MAINS WIRES.
7.
REMOVE BULB SOCKET(S), FIXTURE WIRE, BULB BRACKETS, AND/OR FLUORESCENT BALLAST FROM 
FIXTURE. 
8.
ROUTE LED RETROFIT WIRE HARNESS (1-WHITE, 1-BLACK OR BLUE, 1-GREEN WIRE) WIRES 
THROUGH WIRE OPENING IN FIXTURE. CONFIRM WIRES WILL NOT BE PINCHED BY ROUND LED 
MOUNTING PLATE OR OTHER FIXTURE HARDWARE WHEN REASSEMBLED. 
a.
IF FIXTURE WIRE OPENING IS BLOCKED BY ROUND LED RETROFIT MOUNTING PLATE, 
DRILL 3/8-INCH DIAMETER HOLE IN FIXTURE AND USE INCLUDED GROMMET. 
Ceiling Fixture
Incandescent
Ceiling Fixture
Ballasted Fluorescent
Ceiling Fixture
Ballast and Wires Removed