400 series amplifier box, Fuse locations on relay pcb fuse chart, Psrn4anr1 psrn4anr2 powered output wiring – SoundOff Signal 400 Series Handheld Siren User Manual
Page 5
1.800.338.7337 / www.soundoffsignal.com
50A
FUSE
50A
FUSE
Slide Switch Level 3 Output
YELL
OW
GREEN
BL
UE
RED
RED
GREEN/WHITE
GREEN
RED
GREY
VIOLET
WHITE
Relay #9 Output for
2 wire Arrow Control Interface
Auxiliary Push Button #8
Normally Closed Output
Slide Switch Level Outputs 1-3 and Button Outputs 1-6 are
active high (vehicle supply level).
G
G
G
Wire Length Minimum Wire Gauge
0-10 Feet
10 AW
10-15 Feet
8 AW
15-25 Feet
6 AW
25+ Feet
Consult Factory
Wire capacity requirements for Relay
incoming power supply for each wire
Internal Relay Board Fuse replacement:
To replace fuses:
1. Remove power connectors CN8 and CN6 or remove power
to unit.
2. Remove unit from console or obtain access to full top of unit.
3. Depress snaps on top cover and lift open.
4. See chart below for output fuse locations and ratings.
5. Fuse Ratings: Replace with same rated part.
6. Close cover, reinstall connectors and reinstall unit in console.
The button outputs 7 and 8 have the ability to receive power from
an independent external power source or from the internal +V as
supplied to CN8. Both of these outputs use a separate internal
10A mini-ATO fuse which rely on position to determine the source
selection. Each fuse may be placed in one of 2 locations. See
diagram below.
* If the fuse is placed in the fuse holder near the back edge
of the PCB that output will be powered from an external source,
labeled “relay #(x) input” on CN3.
** If the fuse is placed in the fuse holder away from the back
edge of the PCB that output will be powered from the internal +V
source that comes from CN8 pin 5.
**INTERNAL
*EXTERNAL
RED/ BLACK
GREEN/ BLACK
RED/ WHITE
ORANGE
YELLOW
BROWN
BLUE
Auxiliary Push-Button 7 Normally Open Output
*
Auxiliary Push-Button 8 Normally Open Output
*
Auxiliary Push-Button 7 Normally Closed Output
*
Push-Button 4 Output
Push-Button 3 Output
Push-Button 2 Output
Push-Button 1 Output
Slide Switch Level 2 Output
Slide Switch Level 1 Output
+ V
+ V
CN3
CN8
CN5
FUSE LOCATIONS ON RELAY PCB
FUSE CHART
LOCATION RATING
FB-8
10A
FB-7
10A
FB-4
10A
FB-3
10A
FB-2
10A
FB-1
10A
FB-5
10A
FB-6
10A
FB-9
10A
FS-1
20A
FS-2
20A
FS-3
20A
AUXILARY PUSH BUTTON
8 7 4 3 2 1 5 6 9
SLIDE SWITCH
1 2 3
Not used
Relay #8 Input
Relay #7 Input
Auxiliary Push Button #6 Output
Auxiliary Push Button #5 Output
RJ45 Cable to Control Panel
400 SERIES AMPLIFIER BOX
PSRN4ANR1
PSRN4ANR2
POWERED
OUTPUT WIRING
5
ETSA46(x)HPP 11.13
CONTROL PANEL
PSRN4CTRL1
OR
HANDHELD REMOTE
PSRNHHC1
5 4
3 2 1
NOTE:
= Not used on Hand Held Version
*
*
*
*
Right Alley for signle button Alley control
To Device requiring power
only when Ignition Switch
is on
From Siren
Switch Output
+V when Ignition
Switch is ON
NORMALLY OPEN
CONTACT RELAY
1 Amp
1 1
2 2
3
5
NOTICE:
When an output is connected to a
device which is required to function
only when ignition switch is ON, a
relay needs to be installed in-line with
the siren switch output to ensure an
operator can’t activate the device
without the ignition switch ON.
See wiring diagram details: