beautypg.com

SoundOff Signal INTELLIswitch993 Switch w/ Power Pursuit User Manual

Etsp993 smart panel wiring instructions, Function table

background image

ETSP993 Smart Panel Wiring Instructions

1. If a switch has been associated with the Pursuit switch,
it can always be operated normally by pushing one (1)
time to turn ON and a second (2nd) time to turn OFF.
2. If a switch has been associated with and turned on via
the Pursuit switch it can be turned OFF by pushing it one
(1) time.
3. If no buttons are pressed for one (1) minute while in
programming mode, the unit will save the current settings
and exit programming mode automatically.

Operation Notes

Wire

1
2
3
4
5
6
7
8
9

10

AWG

20
20
20
20
20
20
20
20
20
14

Color
Green
Yellow
Orange
Brown
Gray
Violet
Black
Tan
Blue
Red

Item
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
Switch 6
Ground
Ignition
Gun Lock
Power

Function

Ground
Ignition
Gun Lock
Power

ETSP993
Thank you for purchasing this SoundOff Signal product. With proper
installation and care, this unit will provide years of trouble-free service.

Use an Available
Bolt/Hole or a
Self Tapping Screw
Star Washer
Ring Terminal
Vehicle Frame

A loose chassis ground
connection WILL cause
intermittent operation!

Chassis Ground

Scrape away any paint from the selected bolt
hole and use a star washer and ring terminal
to ensure a good, secure electrical connection
to the chassis. The chassis ground must not
be an insulated point.

Note: When drilling into any vehicle
structure, ensure that both sides of the
surface are clear of anything that can be
damaged.

To (-) Black Ground
(12 AWG)

Function Table

1. Install RED (J4-1) Power wire. Protect the circuit with a 15 Amp
fuse (not supplied).
2. Install BLACK (J3-3) to Chassis Ground wire.
3. Install TAN (J3-2) to an ignition +12v circuit, 100mA input.
4. Install all of the outputs 1 through 6 to the various light bar outputs
and other lights, (2 amps each output).
5. Install blue wire to Gun Lock output (+12v signal).
6. Test installation of each light by pressing corresponding switch on
Smart Panel.

Auto - Walk - About Test
Enter Auto-Walk-About mode by holding down switches 1 & 6 at the same time for 5 seconds.

This test automatically turns each output (1 - 6) ON and OFF at a 5-second interval. The test runs for 120-seconds and can be exited
at anytime by pressing any pursuit switch. The test can be reset by pressing any switch 1 - 6.

3

J1

J4

2A FUSE

POWER

+12V

INPUT

15 AMP FUSE

CUSTOMER

SUPPLIED

Panel Back Inside View

SW
# 1
OUT

2

SW
# 2
OUT

1

SW
# 3
OUT

3

J2

SW
# 4
OUT

2

SW
# 5
OUT

1

SW
# 6
OUT

3

J3

CHS
GND
IN

2

IGN
+12V
IN

1

GUN

LCK

+12v

OUT

(2A MAX)

All outputs 2 amps

GRN

YEL

ORG

BRN

GRY

VIO

BLK

TAN

BLU

Function column intentionally left blank. Please fill in
appropriate functions and store in glove box for future
reference / tech support.

ETSP993_C.CDR 2011-05-08

Page -1-

1.800.338.7337 / www.soundoffsignal.com / Thank you for trusting us with your safety!

SoundOff Signal

3900 Central Parkway

Hudsonville, MI 49426

Ph: 800.338.7337
Ph: 616.896.7100

Fx: 616.896.1286

Warning: In standard format, each switch is ONLY rated for a maximum 2 Amp load per switch!
Should your amp draw requirements exceed 2 Amps per switch, call 800-338-7337 to order our
optional in-line 40 Amp relay kit, part number PSP0RK1. This kit will increase the maximum amp
load capacity of one switch/lead to 40 Amps. List Price is $35.30 each.

NST12020-2_C

Table of contents