APPENDIX II : SYNSCAN SELF-DIAGNOSIS
The SynScan hand control contains a built-in self-diagnosis program. To run a full test, users
should prepare two “Loop-Test Plug” by referring to
Appendix 3
and the following instructions:
• Short the pin-5 (RX_TTL) and pin-6 (TX_TTL) of a RJ-45 plug.
• Short the pin-2 (TX_RS232C) and pin-5 (RX_RS232C) of a RJ-12 plug.
Here are the diagnosis steps:
1.
Insert the two “Loop-Test Plug” to the corresponding port of the SynScan hand control.
2.
Press “
2
” and “
5
” simultaneously and power on the hand control.
3.
The hand control will give a short beep and display “
SynScan B.I.T.
” for a short time.
4.
The LCD screen will become fully black and then fully clear for a while for the purpose of
checking the LCD display.
5.
If there is any problem for the RS-232C function on multi-purpose port (the RJ-12 outlet)
or no Loop-Test Plug connected to the multi-purpose port, the screen will display “
COM1
ERROR
”. Press
ENTER
to continue.
6.
If there is any problem on the mount port or no Loop-Test Plug connected to the mount port
(the RJ-45 outlet), the screen will display “
COM2 ERROR
”. Press
ENTER
to continue.
7.
If everything is fine, the testing will go to
Step 8
; Otherwise, the SynScan hand control will
show “
EEPROM ERROR
” or “
Flash ERROR
”. Press
ENTER
to continue in such case.
8.
Check keypad and other features:
• The screen will display “
Key=
” in the top row. If a key is pressed, the name of the key
will be displayed, and the hand control also beeps while the key is pressed.
• Power voltage and the temperature will be displayed on the bottom row of the screen.