Sky-Watcher SynScan V3 Hand Controller User Manual
Page 36
36
PART XI : ADVANCED FUNCTIONS
The polar alignment function can help users to polar align an equatorial mount accurately.
Here are the operating instructions:
11.3 Polar Alignment without Polar Scope
1.
Complete a 2-star alignment or a 3-star alignment. At the end of the alignment, the Syn-
Scan hand control will display the polar alignment error
(refer to Section 3.3)
. Users can
use the data to determine whether it is necessary to adjust the polar alignment.
2.
Press the “
SETUP
” shortcut key, and then access to sub-menu “
Alignment\Polar Align. >
”,
press the
ENTER
key to proceed to the next step.
3.
The screen will display “
Select a Star
”.
4.
Use the direction keys to center the reference star in the eyepiece of the telescope after
the mount stops slewing. Remember to end the centering operation with
Up
and
Right
direction keys. Press the
ENTER
key to proceed to the next step.
5.
The screen will now display the polar alignment error in altitude (Mel=dd’mm’ss”). Users
can then use the data to determine whether or not to adjust the altitude of the R.A. axis in
the next step. Press the ENTER key to proceed.
6.
The mount will slew to a new position. When it stops, the screen will display “Adjust
Altitude:”. By using ONLY the altitude control of the mount (do not touch the azimuth
control), bring the reference star back to the closest point to the center of the FOV of the
telescope’s eyepiece. Remember the reference star’s current position in the eyepiece for
later adjustment. Press the ENTER key to confirm the centering operation.
7.
The screen will now display the polar alignment error. Users can then use the data to
determine whether or not to adjust the azimuth of the mount in the next step. Press the
ENTER key again to proceed to the next step.
8.
The mount will slew to a new position. When it stops, the screen will display “Adjust Azi-
muth:” By using ONLY the azimuth control of the mount (do not touch the altitude control),
bring the reference star back to the closest point to the previous position (at the end of
Step 6). Press the ENTER key to confirm the centering operation.
9.
The screen will display the polar alignment error again, press the ENTER button to end
the polar alignment process.
10.
Go back to the “
Alignment
” menu on the SynScan hand control and execute another
2-Star or 3-Star alignment, and then check the polar alignment error data reported at the
end of the 2-star alignment or 3-star alignment. Repeat Step 2 to Step 9 until the error
is small enough and acceptable. Generally, users can get up to 1 arc-minute polar align-
ment accuracy after repeating this polar alignment process 2 or 3 times.
Note:
• Users can press the
ESC
key at any time during the polar alignment process to exit.
• Use the scroll keys to browse through a list of star names and press the
ENTER
key to
pick one as the reference star for polar alignment.
• The mount will start slewing to point the telescope to the reference star.