5 transport, storage and disposal, 1 storage, 2 return consignments – Richter RSS/F Series Bellows-Sealed Control Valves User Manual
Page 11: 3 disposal, 6 installation, 1 flange caps and gaskets, 5 transport,storage and disposal, Storage, Return consignments, Disposal

Series RSS/F
Page 11
9260-060-en
Revision 03
TM 7168
Edition 06/2008
5
Transport, storage and disposal
It is imperative, for all transport work, to observe
generally accepted engineering practice and 
the accident prevention regulations. 
The valve is supplied with flange caps. Do 
not remove them until just before installation. 
They protect the plastic surfaces against dirt 
and mechanical damage. 
Handle the goods being transported with care. During 
transport the valve must be protected against impacts 
and collisions. 
Directly after receipt of the goods, the consignment 
must be checked for completeness and any in-transit 
damage. 
Do not damage paint protection. 
 
5.1 Storage
If the valve is not installed immediately after delivery, it 
must be put into proper storage. 
It should be stored in a dry, vibration-free and well-
ventilated room at as constant a temperature as 
possible. 
Elastomers are to be protected against UV light. 
In general, a storage period of 10 years should not be 
exceeded. 
5.2 Return
consignments
Valves which have conveyed aggressive or toxic
media must be well rinsed and cleaned 
before being returned to the manufacturer's 
works. 
It is imperative to enclose a safety information 
sheet / general safety certificate on the field of 
application with the return consignment. 
Pre-printed forms are enclosed with the installation 
and operating manual. 
Safety precautions and decontamination measures 
are to be mentioned. 
 
5.3 Disposal
Parts of the valve may be contaminated with medium 
which is detrimental to health and the environment and 
therefore cleaning is not sufficient. 
Risk of personal injury or damage to the 
environment due to the medium! 
Wear protective clothing when work is performed 
on the valve. 
Prior to the disposal of the valve: 
Collect any medium, etc. which has escaped and 
dispose of it in accordance with the local regula-
tions. 
Neutralise any medium residues in the valve. 
Separate valve materials (plastics, metals, etc.) 
and dispose of them in accordance with the local 
regulations. 
6
Installation
Examine valve for in-transit damage, damaged 
bellows control valves must not be installed. 
Before installation the valve and the connecting 
pipe must be carefully cleaned to remove any dirt, 
especially hard foreign matter. 
During installation, pay attention to the correct 
tightening torque, aligned pipes and tension-free 
assembly. 
The all-round gap between the body and the cover 
must remain constant so that a centric position of 
the plug in relation to the seat is guaranteed. 
Operation during maintenance work can be 
continued with a bypass around the control valve. 
Ensure that a remotely actuated actuator 
cannot be accidentally switched on. 
Depending on the kv-value, the free cross section 
in the valve may be much smaller than the cross 
section of the nominal size. To prevent clogging, 
the pipe must be carefully cleaned upstream of the 
valve. 
6.1 Flange caps and gaskets
Leave protective caps on the flanges until just prior to 
installation. 
Where there is a particularly high risk of damage to 
the plastic sealing surfaces, e.g. if the mating flanges 
are made of metal or enamel, PTFE-lined gaskets with 
a metal inlay should be used. These gaskets are 