2 safety, 1 intended use, Intended use – Richter RMI-B Series User Manual
Page 5: 2safety, Series rmi-b, Close-coupled design

Series RMI-B
close-coupled design
Page 5
9470-055-en
Revision 02
TM 8256
Edition 06/2011
2
Safety
This operating manual contains fundamental 
information which is to be observed during installation, 
operation and maintenance. 
It must be read before installation and 
commissioning! 
This operating manual must always be available at the 
place of use of the machine/plant. 
Observe the safety notes in all the chapters. 
Installation, operation and maintenance are to be 
performed by qualified staff. 
The area of responsibility, authority and supervision of 
the staff must be exactly regulated by the customer. 
If the staff does not have the necessary expertise, 
they are to be trained and instructed. 
If necessary, this can be provided by the 
manufacturer/supplier on behalf of the machine 
operator. 
General hazard symbol! People may be put 
at risk. 
Safety symbol! The pump and its function 
may be put at risk if this safety symbol is not 
observed. 
EU marking! Explosion-protected equip-
ment must be identified for work in 
potentially explosive areas. 
Warning of a magnetic field!
Warning of electric power!
This warning sign must be used if people 
with a pacemaker are at risk, e.g. from a 
strong magnetic field. 
It is imperative to observe signs attached directly to 
the pump / unit, e.g.: 
Direction of rotation arrow 
Warning against dry-running 
and they are to be kept legible. 
Non-observance of the notes on safety may result 
in the loss of any and all claims for damages. 
Non-observance may involve the following hazards : 
Failure of important functions of the machine/plant. 
Failure of electronic equipment and measuring 
instruments due to magnetic fields. 
Risk to people and their personal property from 
magnetic fields. 
Risk to people from electric, mechanical and 
chemical effects. 
Risks to the environment through leaks of 
hazardous substances. 
If the unit is used in potentially explosive areas, 
special attention is to be paid to the sections 
identified with “Ex” in this operating manual. 
2.1 Intended use
Richter pumps of the series RMI-B are plastic-lined 
magnetic drive centrifugal pumps for the leak-free 
conveyance of aggressive, toxic, pure and 
inflammable liquids.The pump is equipped with a 
permanent magnetic synchronous drive. 
Only operate the pump / the unit in a technically 
perfect condition. 
Only use the pump with the media described in the 
data sheet. 
For vertical installation of the pump, please consult 
the manufacturer. 
The observance of the specified physical limits is 
important for perfect functioning and safe operation, 
especially with regard to explosion protection to 
prevent potential sources of ignition (see Chapter
2.6): 
Avoid dry running. 
Make sure that the pump is only operated with a 
medium and not without one. 
For safe pump operation, we recommend a flow 
rate which lies between 0.3 and 1.1 Q
opt
.
The
maximum operating temperature must never be 
exceeded. See Chapter 2.6.7. In case of doubt, 
you must consult the manufacturer. 
The manufacturer must be consulted in the event 
of entrainment of gas >2% as well as solids in 
order to avoid a lack of lubrication and dry-running. 
The plant NPSH value (NPSHA) should be 0.5 m 
higher than the NPSH value of the pump 
(NPSHR). See also Chapter 5.4.1.
Improper operation, even for brief periods, 
may result in serious damage to the unit. 
In connection with explosion protection, 
potential sources of ignition (overheating, electrostatic 
and induced charges, mechanical and electric sparks) 
can result from these inadmissible modes of 
operation; their occurrence can only be prevented by 
adhering to the intended use. 
Furthermore, reference is made in this connection to 
the Directive 95/C332/06 (ATEX 118a) which contains 
the minimum regulations for improving the 
occupational health and safety of the workers who 
may be at risk from an explosive atmosphere. 
Do not operate the unit above the values 
specified in the data sheet for the 
fluid 
flow rate 
speed 
density 
head 
operating temperature and 
motor rating 