beautypg.com

8 malfunctions, 8malfunctions, Series rmi-b – Richter RMI-B Series User Manual

Page 21

background image

Series RMI-B

close-coupled design

Page 21

9470-055-en

Revision 02

TM 8256

Edition 06/2011

8

Malfunctions

Faults may result from inadmissible modes of
operation. Improper operation, even for brief
periods, may result in serious damage to the

unit.
In connection with explosion protection, potential
sources of ignition (overheating, electrostatic and
induced charges, mechanical and electric sparks) can
result from these inadmissible modes of operation;
their occurrence can only be prevented by adhering to
the intended use.
See also Chapter 6.5.
Should there be any uncertainty about the remedy to
be applied, please inquire at the in-house pump office
or at the pump manufacturer's.

No delivery :

Is the pump filled and vented?
Is the suction line open, vented, cleaned and
correctly laid?
Is the discharge line open, vented, cleaned and
correctly laid?
Is the geodetic head too high?
Is air being drawn in?
Has the magnetic drive stopped?

Flow rate too low :

Have the pump, suction line and discharge line
been completely vented, filled and cleaned?
Have any strainers installed been cleaned?
Are all shut-off devices open?
Is the geodetic head too high?
Is the NPSHA too low or the NPSHR too high?
Are the pipe resistances too high?
Is the viscosity too high?
Is the direction of rotation correct?
Is the speed too low or the impeller diameter too
small?
Are pump parts worn?
Gas in the medium?

Flow rate too high :

Is the geodetic head too low?
Are the pipe or nozzle resistances too low?
Is the pump speed too low or the impeller
diameter too large?

Delivery pressure too high :

Is the speed too high or the impeller diameter too
large?
Is the density too high?

Motor consumes too much electricity :

Is the flow rate, density or viscosity too high?
Is the speed too high or the impeller diameter too
large?
Is the coupling correctly aligned?
Can the pump shaft be turned properly?

Pump does not run smoothly or creates
noises :

Are the ball bearings on the motor damaged?
Are parts of the hydraulics damaged?
Is the flow rate too low or too high?
Is the impeller balanced?
Is the pump twisted?
Is there foreign matter in the pump?

Leak from the pump :

Are all screws tightened to the correct tightening
torque?
Were the sealing surfaces assembled in a clean
state?
Have approved gaskets been installed?