6 malfunctions, Seal, 6malfunctions – Richter RSI Series User Manual
Page 7: Series rsa
Series RSA
,
Mechanical Seals, external, single or
Page 7
double, type Crane 58U – 58U
9485-060-en
Revision 11
TM 8046
Edition 10/2010
5.2.3 Assembly bracket chamber
double mechanical seal
Press mating ring on the atmosphere side 475/2
with O-ring 412/7 into the seal housing 483. Pay
attention to the correct positioning of the mating
ring 475/2 in relation to the spring-type slotted pin
531/1.
CAUTION: If assembly is not accurate,
there is a risk of breakage to the mating
ring.
Insert pre-assembled unit of the seal housing into
the appropriate centering of the bearing pedestal
330.
Pay attention to the correct positioning of the three
rear recesses of the seal housing 483 (positions 3,
6 and 9 o'clock).
Mount rotating units 470/1 and 470/2 including the
key 940/2 onto the protective shaft sleeve 524.
Pay attention to the correct positioning of the
rotating units (protective shaft sleeve 524 has two
semi-circular recesses on the motor side).
Insert shaft sleeves 523/2 and 523/3 into the
protective shaft sleeve 524.
Carefully introduce pre-assembled unit of the
protective shaft sleeve into the seal housing 483.
Make sure that the two semi-circular recesses of
the protective shaft sleeve 524 engage in the
parallel pins 562/1 of the shaft 210.
For this purpose turn the shaft 210 beforehand so
that the two parallel pins 562/1 in the recesses of
the seal housing 483 can be seen at 3 and 9
o'clock.
CAUTION: If assembly is not accurate,
there is a risk of breakage on the
protective shaft sleeve.
Insert intermediate ring 509/1 into the seal housing
483.
CAUTION: If assembly is not accurate,
there is a risk of breakage on the
mating ring.
Insert mating ring carrier 476 into the seal housing
483.
CAUTION: If assembly is not accurate,
there is a risk of breakage at the
protective shaft sleeve and the mating
ring carrier.
Tighten hex. screws 901/10 in diametrically
opposite sequence.
Tightening torque group 1 = 398 in-lbs (45Nm)
Tightening torque group 2 = 486 in-lbs (55Nm)
Tighten hex. screws 901/4 of the connection seal
housing 483 – bracket 344 in diametrically oppo-
site sequence.
Tightening torque group 1 = 160 in-lbs (18Nm)
Tightening torque group 2 = 212 in-lbs (24Nm)
Screw pipe connectors 917/1 and 917/2 into the
seal housing 483.
RSA 9485-050-en or RSI 9480-050-en.
6
Malfunctions
Faults may result from inadmissible modes of
operation. Such improper operation – even
brief ones – may cause serious damage to the
unit.
In connection with explosion protection, potential
sources of ignition (overheating, electrostatic and
induced charges, mechanical and electric sparks) can
result from these inadmissible modes of operation;
their occurrence can only be prevented by adhering to
the intended use.
See also Section 2.1.
Should there be any uncertainty about the remedy to
be applied, please inquire at the in-house pump office
or at the pump manufacturer's.
See also Section 8 in the installation and operating
manual of the RSA series.