1 tightening torques, 2 type plate, dry-running, ce and housing markings, Tightening torques – Richter MNK-B Series User Manual
Page 4: Markings, Series mnk-b, Close-coupled design

Series MNK-B,
close-coupled design
Page 4
9230-055-en
Revision 09
TM 7345
Edition 10/2008
1.1 Tightening torques
Screws greased, tighten in diametrically opposite
sequence
Housing screws 901/3
Size
No. x size
Tightening torque
[mm]
[DIN/ISO]
[Nm]
25-25-125
8 x M 10
20
50-32-125
8 x M 10
20
25-25-160
6 x M 10
45
50-32-160
6 x M 10
45
80-50-160
6 x M 10
45
50-32-200
8 x M 12
45
65-40-200
8 x M 12
45
80-50-200
8 x M 12
45
Pipe screws, flanges to DIN/ISO
DN
No. x size
Tightening torque
[mm]
[DIN/ISO]
[Nm]
25
4 x M 12
10
32
4 x M 16
15
40
4 x M 16
20
50
4 x M 16
26
65
4 x M 16
40
80
8 x M 16
25
Pipe screws, DIN/ISO flanges drilled to ASME
DN
No. x size
Tightening torque
[mm] [inch]
[ASME]
[Nm]
[in-lbs]
25
1“
4 x ½“
8
70
32
1¼“
4 x ½“
12
105
40
1½“
4 x ½“
15
135
50
2“
4 x N“
25
220
65
2½“
4 x N“
30
265
80
3“
4 x N“
45
400
1.2 Type plate, dry-running,
CE and housing markings
The stainless steel type plate is firmly riveted to the
housing:
If the operator attaches his identification, it must be
ensured that the pump matches the application in
question.
Example of type plate:
Dry-running:
CE marking:
(only for pumps to ATEX 95)
Housing identification:
The following are visible on the housing according to
DIN EN 19:
Nominal size
Rated pressure
Housing material
Manufacturer's identification
Melt number/Foundry identification
Cast date