Manual Operation

The Ballast operates remote from the fixture. Connect the Extension cable

to the Ballast and the Lamp Harness. After the lamps are properly installed,

the Ballast can be turned on. Each switch controls one lamp. The color

bands on the lamp harness correspond to the switches as illustrated.

Lamp Select Feature

The Mega Ballasts have an

HO/Std switch. Set the selector switch to HO for

High Output and

Std for Standard light output.

When operating 8ft or 6ft lamps in high ambient temperature or where the

units are rigged into place with restricted airflow, the

Std setting can be used

to lower the color temperature and remove any green spike. The light drops

about a half f-stop in exposure when dropping from

HO to Std.