Use only gaskets that have been specified by the manufacturer or the supervising
engineer. Be certain that they are clean and fresh with no bumps, tears or serious
imperfections.
Using a torque wrench, tighten the fasteners in a regular pattern to avoid uneven loads
on the glass. It is necessary to torque individual fasteners in small amounts, moving
to the next fastener after each increment of torque. A maximum difference of 3 FT-
LBS. between fasteners should be maintained on larger units; there should be less on
smaller units. Continue torquing until the value recommended for the unit is attained.
See also other documents in the category Kenco Engineering Sensors:
- KUST Switch (4 pages)
- KUSG Switch (4 pages)
- KUSO Switch (2 pages)
- Thermal Differential Switch (8 pages)
- SmartSonic Transmitter (Remote) (37 pages)
- SmartSonic Transmitter (Integral) (30 pages)
- KMD Transmitter (17 pages)
- KMD Transmitter (13 pages)
- Magna-Site Magnetic Level (3 pages)
- Magna-Site Magnetic Level Gauge (MLG-D) (1 page)
- 9958 - 360 Degree Magnet (1 page)
- 9958 - Bar Magnet (1 page)
- K9900 Series Level Gauge (2 pages)
- K9900 Series Level Gauge (flanged) (2 pages)
- 8800 Series Level Gauge (2 pages)
- KTV Tubular Valves (2 pages)
- 5700 (1 page)
- 17000 (1 page)
- 17000 Sight Tube Replacement (1 page)
- Flat Glass Level Gauge (4 pages)
- Flat Glass Gauge Valve (4 pages)
- Weld Pad Flat Glass Level Gauge (4 pages)
- ESP Series Level Gauge (2 pages)
- FVSF Sight Flow Indicator (4 pages)
- Chemical Injectors (standard and mini) (2 pages)
- Chemical Injector (retractable) (2 pages)
- 512 (old style) (5 pages)
- 512-TB (old style) (1 page)
- KLCE-DPDT (6 pages)
- KLCE (6 pages)
- KHL-DPDT (6 pages)
- KHL (6 pages)
- KSHL (6 pages)
- KSLL (6 pages)
- KLCM (4 pages)
- KLCP (4 pages)
- KLC (4 pages)
- KPS (4 pages)
- K507-L (1 page)
- KEFS (4 pages)
- KDV DumpValve (4 pages)