Glass replacement for esp/st level gauges – Kenco Engineering ST Series Level Gauge User Manual
Page 2

GLASS REPLACEMENT FOR ESP/ST LEVEL GAUGES
1.
REMOVE HARP PINS FROM CLEVIS PINS ON END GAUGE.
2.
CAREFULLY REMOVE TEFLON TUBE HOLDER INSERT FROM EACH
END OF GAUGE.
3.
REMOVE O-RINGS FROM GLASS AND SLIDE GLASS OUT OF UNIT
(FOR UNITS WITH SIGHT TUBE SPLICER, IT WILL BE NECESSARY TO
REMOVE ONE OF THE TEFLON SIGHT TUBE HOLDERS IN ORDER TO
REMOVE THE GLASS).
4.
IF UNIT HAS A SIGHT TUBE SPLICER, IT WILL BE NECESSARY TO
UNSCREW THE SIGHT TUBE SPLICER ASSEMBLY IN ORDER TO
REPLACE THE GLASS.
5.
SLIDE GLASS BACK INTO UNIT AND REINSTALL O-RINGS (IF UNIT
HAS SIGHT TUBE SPLICER RE-ASSEMBLE SPLICER).
6.
REPLACE TEFLON TUBE HOLDER INSERTS ON BOTH ENDS.
7.
RE-ALLIGN TUBE HOLDER WITH HOLES IN HOUSING AND INSTALL
CLEVIS PIN IN EACH END OF GAUGE AND RE-INSTALL HARP PINS
INTO CLEVIS PINS.