5. Installation of sight tube is as follows:

a. Insert sight tube into splicer if one exists. If a teflon shrink-tube type splicer exists, it will be necessary to
place teflon o-ring cushion between adjoining sight tubes and heat-shrink teflon splicer in place.

b. Slide 1-1/4” square x 1/4” thick o-ring compression plates onto each end of sight tube.

c. Slide o-ring seals onto each end of sight tube.

d. Push end of sight tube into hole in block inside frame on upper end of gauge as far as is required to enable
lower end of sight tube to swing over and into hole in block inside frame on lower end of gauge.

e. Install hex socket head cap screws into blocks on each end of gauge and thread into holes in 1-1/4” square
x 1/4” thick o-ring compression plates and tighten securely.