beautypg.com

Warning, Troubleshooting, Maintenance – Garden Sun Heater HSS-A-GH Standard Lift Up User Manual

Page 13

background image

12

Troubleshooting

If the problem is:

And this condition exists:

Then do this

Pilot won’t light

Cylinder valve is closed

Open valve

Blockage in orifice or pilot tube

Clean or replace orifice or pilot tube

Air in gas line

Open gas line and bleed it (pressing control

knob in) for not more than 1 - 2 minutes or

until

you smell gas

Low gas pressure with cylinder valve

fully open

Turn cylinder valve OFF and replace cylinder

Note:

Heater

operates

at

reduced efficiency below 40ºF

(5ºC)

Igniter fails

Use match to light pilot; obtain new igniter and

replace

Pilot won’t stay lit

Dirt built up around pilot

Clean dirt from around pilot

Connection between gas valve and

pilot assembly is loose

Tighten connection and perform leak check

Thermocouple is not operating correctly

Replace thermocouple

Burner won’t light

Gas pressure is low

Turn cylinder valve OFF and replace cylinder

Blockage in orifice

Clear blockage

Control knob is not in ON position

Turn control knob to ON

Burner flame is low

Gas pressure is low

Turn cylinder valve OFF and replace cylinder

Outdoor temperature is less than 40ºF

and tank is less than 1/4 full

Use a full cylinder

Supply hose is bent or kinked

Straighten hose

Control knob fully ON

Check burner and orifices for blockage

Carbon build-up

Dirt or film on reflector and burner screen

Clean reflector and burner screen

Thick black smoke

Blockage in burner

Remove blockage and clean burner inside and

outside

Maintenance

WARNING

FOR YOUR SAFETY:

• Do NOT touch or move heater for at least 45 minutes

after use.

• Reflector is hot to the touch.

• Allow reflector to cool before touching.

To enjoy years of outstanding performance from your

heater, make sure you perform the following maintenance

activities on a regular basis:

Air flow must be unobstructed. Keep controls, burner,

and circulating air passageways clean. Signs of possible

blockage include:

a. Keeping the appliance area clear and free from combustible

materials , gasoline and other flammable vapors and liquids.

b. Not obstructing the flow of combustion and ventilation air.

Keep exterior surfaces clean.

Use warm soapy water for cleaning. Never use

flammable or corrosive cleaning agents.

While cleaning your unit, be sure to keep the area around the

burner and pilot assembly dry at all times. Do not submerge the

control valve assembly. If the gas control is submerged in water,

do NOT use it. It must be replaced.

c.Keeping the ventilation opening(s) of the cylinder enclosure

free and clear from debris.