Warning, Danger – Garden Sun Heater HSS-A-GH Standard Lift Up User Manual
Page 10
9
Leak Check
WARNING
• Perform all leak tests outdoors.
• Extinguish all open flames.
• NEVER leak test when smoking.
• Do not use the heater until all connections have been leak
tested and do not leak.
Make 2-3 oz. of leak check solution (one part liquid
dishwashing detergent and three parts water).
Apply several drops of solution where hose attaches
to regulator.
Apply several drops of solution where regulator
connects to Cylinder.
Make sure all Patio Heater & Light valves are OFF.
Turn Cylinder Valve ON.
If bubbles appear at any connection, there is a leak.
Turn Cylinder Valve OFF.
If leak is at Hose/Regulator connection: tighten
connection and perform another leak test. If bubbles
continue appearing should be returned to Hose’s place
of purchase.
If leak is at Regulator/Cylinder Valve connection:
disconnect, reconnect, and perform another leak
check. If you continue to see bubbles after several
attempts, cylinder valve is defective and should be
returned to cylinder’s place of purchase.
If
NO
bubbles
appear
at
any
connection,
the
connections are secure.
.
Turn Cylinder Valve OFF.
NOTE: Whenever gas connections are loosened or
removed, you must perform a complete leak test.
.
Complete installation.
Operation
DANGER
• CARBON MONOXIDE HAZARD
• For outdoor use only. Never use inside house, or other
unventilated or enclosed areas. This heater consumes air
(oxygen). Do not use in unventilated or enclosed areas to
avoid endangering your life.
Caution: Do not attempt to operate until you have read
& understand all General Safety Information in this
manual and all assembly is complete & leak checks
have been performed.
Regulator / Cylinder
Connection
Hose / Regulator
Connection