background image

®

WATER QUALITY & CONDITIONING PRODUCTS

Watts

®

commercial membranes

Part Number

Application

O.D.

Length

Capacity

No. Per

(GPD)

Case

W-2521-TW

Tap water

2-1/2"

21"

300

1

W-2540-TW

Tap water

2-1/2"

40"

800

1

W-4021-TW

Tap water

4"

40"

1,050

1

W-4040-TW

Tap water

4"

40"

2,200

1

W-4040-BW

Brackish water

4"

40"

2,200

1

W-4040-SW

Sea water

4”

40”

2,200

1

Note: Watts commercial membranes are packaged in preservatives. Keep in cool environment if stored for prolonged periods of time.

Watts membrane specifications

Data

W-2521-TW

W-2540-TW

W-4021-TW

W-4040-TW

W-4040-BW

Membrane type

TFC

TFC

TFC

TFC

TFC

Material

Polyamide

Polyamide

Polyamide

Polyamide

Polyamide

Charge

Negative

Negative

Negative

Negative

Negative

Configuration

Spiral-wound

Spiral-wound

Sprial-wound

Spiral-wound

Sprial-wound

Salt rejection

99.5%

99.5%

99.5%

99.5%

99.5%

Max. operating temp.

113°F / 45°C

113°F / 45°C

113°F / 45°C

113°F / 45°C

113°F / 45°C

Max. operating pressure

400 psi

400 psi

400 psi

400 psi

600 psi

Maximum turbidity (NTU)

<1

<1

<1

<1

<1

Max. SDI

<5

<5

<5

<5

<5

pH range (cleaning)

2-11

2-11

2-11

2-11

2-11

Flux (GPD)

300

800

1,050

2,200

2,200

Note: Tap water membrane specifications are based on 225 psi pressure and 77°F temperature.

Watts

®

membranes

We offer a complete line of residential and commercial membranes for tap, brackish and sea
water applications. Our thin film composite membranes meet or exceed industry standards, with
salt rejection rates ranging from 96 to 99.5 percent. Commercial membranes are listed below.

CONCENTRATE

PERMEATE

FEED

A

U-cup Brine Seal

Outer Tapping

End Cap

B

C

CONCENTRATE

Dimensions: A = 4.0”; B = 40”; C = 0.75”.