Watts FMRO5GP-115V User Manual
Reverse osmosis systems, Reverse osmosis diagram, For safe, great tasting drinking water
Reverse Osmosis Systems
For safe, great tasting
drinking water.
FEED WATER GUIDELINES
Maximum TDS
1,800 ppm
Iron, max.
0.2 ppm
Hardness, (less than)
7 gpg
Hydrogen sulfide
0.0 ppm
Manganese, (less than)
0.05 ppm
Turbidity, (less than)
1 NTU
Pressure, min. / max, psi
40/100
Temperature, range (F)
40°/100°
pH
3-11
Note: Pretreatment suggested if conditions exceed parameters.
MAINTENANCE & WARRANTY
Pre and post filters
Recommended change every six months for regular usage,
or once a year in light usage. RO membrane change
recommended based on periodic TDS rejection tests.
Typical is every two years.
Warranty
Components are warranted for one year from installation,
excluding membrane, pre & post filters. See installing dealer
for system warranty.
Distributed by:
®
DEDICATED FAUCET
FOR RO WATER
Caution: Do not use where water is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the unit. System
must be maintained according to manufacturer’s instructions.
Reverse Osmosis Diagram
© Watts 2008
B-WQP-RO-0830