Performance, Options, Feed water guidelines – Watts PWRO440 User Manual
Page 2

ES-WQ-PWRO440 1225
© 2012 Watts
USA: Tel. (800) 224-1299 • www.watts.com
Canada: Tel. (888) 208-8927 • www.watts.ca
A Watts Water Technologies Company
PWRO4401
PWRO4402
PWRO4403
Maximum Productivity
(gallons per day) / (lpd)
2200 / 8328
4400 / 16,656
6600 / 24,984
Recovery
(user adjustable)
15 - 75%
25 - 75%
32 - 75%
Number of Membranes
1
2
3
Replacement Membrane
PWMEM2200
Feed Water Required (maximum)
10 gpm (38 lpm)
12 gpm (45 lpm)
14 gpm (53 lpm)
Drain Required (maximum)
10 gpm (38 lpm)
12 gpm (45 lpm)
14 gpm (53 lpm)
Motor Horse Power
3
/
4
1
1
1
/
2
Electrical Requirement
10 amps
12 amps
15 amps
Dimensions W x D x H
20" x 20" x 50"
(600 x 600 x 1270mm)
20" x 20" x 50"
(600 x 600 x 1270mm)
20" x 26" x 50"
(600 x 660 x 1270mm)
Shipping Weight
(estimated lbs)
120 lbs / 54 kgs
150 lbs / 68 kgs
180 lbs / 82 kgs
Performance
*Includes atmospheric storage tank, product float switch, and repressure
pump with built in controls
.
Note: For indoor installation only.
Model No.
descriptioN
PWTNK165PKG
165 gal tank whole house option*
PWTNK300PKG
300 gal tank whole house option*
PWTNK500PKG
500 gal tank whole house option*
Options
Notes: Maximum production based on a feed water of
77°F, SDI < 1, 1000 ppm TDS, and pH 7. Individual mem-
brane productivity may vary (± 15%). May be operated on
other feed waters with reduced capacity. Percent rejec-
tion is based on membrane manufacture's specifications;
overall system percent rejection may be less.
Feed Water Guidelines
pH . . . . . . . . . . . . . . . . . . . . . . . . . 6 to 9
Hardness (maximum) . . . . . . . . . . . Less than 1 grain per gallon as
CaCO3 (Softened) or anti-scale
chemical injection if not softened
(contact your Watts representative)
Feed Water Pressure (minimum) . .20psi
Temperature . . . . . . . . . . . . . . . . .35 - 100°F (2 - 38°C)
Free Chlorine (maximum) . . . . . . . .None Allowed
Iron (maximum) . . . . . . . . . . . . . . . .Less than .1mg/L
Oil and H2S . . . . . . . . . . . . . . . . . .None Allowed
Turbidity . . . . . . . . . . . . . . . . . . . .Less than 1.0 NTU
Silt Density Index . . . . . . . . . . . . . .Less than 5.0 SDI
Notes:
* For all other guideline information please contact your Watts
representative.
Note: Feed Water must be pretreated for scale prevention (softened), de-
chlorinated (Carbon Filter), and free of sediment.