beautypg.com

Performance, Options, Feed water guidelines – Watts PWRO440 User Manual

Page 2

background image

ES-WQ-PWRO440 1225

© 2012 Watts

USA: Tel. (800) 224-1299 • www.watts.com

Canada: Tel. (888) 208-8927 • www.watts.ca

A Watts Water Technologies Company

PWRO4401

PWRO4402

PWRO4403

Maximum Productivity
(gallons per day) / (lpd)

2200 / 8328

4400 / 16,656

6600 / 24,984

Recovery
(user adjustable)

15 - 75%

25 - 75%

32 - 75%

Number of Membranes

1

2

3

Replacement Membrane

PWMEM2200

Feed Water Required (maximum)

10 gpm (38 lpm)

12 gpm (45 lpm)

14 gpm (53 lpm)

Drain Required (maximum)

10 gpm (38 lpm)

12 gpm (45 lpm)

14 gpm (53 lpm)

Motor Horse Power

3

/

4

1

1

1

/

2

Electrical Requirement

10 amps

12 amps

15 amps

Dimensions W x D x H

20" x 20" x 50"

(600 x 600 x 1270mm)

20" x 20" x 50"

(600 x 600 x 1270mm)

20" x 26" x 50"

(600 x 660 x 1270mm)

Shipping Weight
(estimated lbs)

120 lbs / 54 kgs

150 lbs / 68 kgs

180 lbs / 82 kgs

Performance

*Includes atmospheric storage tank, product float switch, and repressure

pump with built in controls

.

Note: For indoor installation only.

Model No.

descriptioN

PWTNK165PKG

165 gal tank whole house option*

PWTNK300PKG

300 gal tank whole house option*

PWTNK500PKG

500 gal tank whole house option*

Options

Notes: Maximum production based on a feed water of

77°F, SDI < 1, 1000 ppm TDS, and pH 7. Individual mem-

brane productivity may vary (± 15%). May be operated on

other feed waters with reduced capacity. Percent rejec-

tion is based on membrane manufacture's specifications;

overall system percent rejection may be less.

Feed Water Guidelines

pH . . . . . . . . . . . . . . . . . . . . . . . . . 6 to 9
Hardness (maximum) . . . . . . . . . . . Less than 1 grain per gallon as

CaCO3 (Softened) or anti-scale

chemical injection if not softened

(contact your Watts representative)

Feed Water Pressure (minimum) . .20psi
Temperature . . . . . . . . . . . . . . . . .35 - 100°F (2 - 38°C)
Free Chlorine (maximum) . . . . . . . .None Allowed
Iron (maximum) . . . . . . . . . . . . . . . .Less than .1mg/L
Oil and H2S . . . . . . . . . . . . . . . . . .None Allowed
Turbidity . . . . . . . . . . . . . . . . . . . .Less than 1.0 NTU
Silt Density Index . . . . . . . . . . . . . .Less than 5.0 SDI

Notes:
* For all other guideline information please contact your Watts

representative.

Note: Feed Water must be pretreated for scale prevention (softened), de-

chlorinated (Carbon Filter), and free of sediment.