Watts R14-06-1111000 User Manual
R-14 floor-mounted systems, Models, Specifications
Models
Model Number
PACK-
AGE
GPD
Pump
(H.P.)
Recovery
(Adj.)
Membrane
Size
Membranes
Feed Water
Required*
(GPM)
Typical
Rejection
Dimensions
Ship
Wt.
(Lbs.)
R14-02-1111000
1
3600
5
25%-75%
4" x 40"
2
5
98%
60"x18"x56"
400
R14-02-1131100
2
3600
5
25%-75%
4" x 40"
2
5
98%
60"x18"x56"
400
R14-03-1111000
1
5400
5
36%-75%
4" x 40"
3
7.50
98%
60"x18"x56"
500
R14-03-1131100
2
5400
5
36%-75%
4" x 40"
3
7.5
98%
60"x18"x56"
500
R14-04-1111000
1
7200
5
42%-75%
4" x 40"
4
10
98%
60"x18"x56"
600
R14-04-1131100
2
7200
5
42%-75%
4" x 40"
4
10
98%
60"x18"x56"
600
R14-05-1111000
1
9000
5
46%-75%
4" x 40"
5
12.5
98%
60"x18"x56"
700
R14-05-1131100
2
9000
5
46%-75%
4" x 40"
5
12.5
98%
60"x18"x56"
700
R14-06-1111000
1
10800
5
50%-75%
4" x 40"
6
15
98%
60"x18"x56"
800
R14-06-1131100
2
10800
5
50%-75%
4" x 40"
6
15
98%
60"x18"x56"
800
Specifications
Feed water connection
1" FNPT
Product water connection
3/4" FNPT
Reject water connection
3/4" FNPT
Feed water pressure requirement (min.)
10 PSIG
Drain requirement (maximum)
15 GPM
Electrical requirement
230VAC/60hz
Phase
3
Amps
15
*At 50% recovery.
®
WATER QUALITY & CONDITIONING PRODUCTS
R-14 floor-mounted systems
Five models for flow rates to 10,800 GPD. Select
the features you want to meet your requirements!
Standard features (package #1)
•
Powder coated steel frame
•
Stainless steel pressure vessels
•
Pre-filter housing and cartridge (20" Full-Flow)
•
Webtrol
®
heavy-duty multi-stage centrifugal pump
•
Automatic inlet valve
•
Low-pressure shut-off with automatic restart
•
Tank level input
•
Pretreatment interlock input
•
Adjustable recycle line
•
Pre-filter pressure gauges
•
Pump discharge pressure gauge (liquid filled)
•
Flow meter for product water
•
Flow meter for reject water
•
Flow meter for recycle water
•
Check valve for product water
•
On / off switch
Additional features included with package #2
•
CI-1000 electronic controller with product
water conductivity meter and alarm output
•
Programmable concentrate auto flush
R14-06-1131100 System
Notes: Performance specifications are based on 77°F feed water, 3 SDI or less, TDS below 1000 and pH of 8. Please see water temperature
conversion charts to determine actual production rate for each installation. Chlorine reduction and other pretreatment may be required.
Membrane rejection rates are based on membrane manufacturer's specifications. Pre-filter is Flow-Pro
®
FPMB-BB5-20 melt blown cartridge.
Systems are designed for use with municipal and well water.