beautypg.com

Watts TBC User Manual

Series tbc, Dial size: 2, 65mm)

background image

C

E

D

A

For Commercial, Residential and Institutional Applications

ES-TBC

Series TBC

Chimney Mount, Center Back

Entry Bimetal Thermometers

Dial Size: 2

1

2

" (65mm)

Series TBC Chimney-Mount, Center, Back-Entry Bimetal

Thermometers are used in commercial, residential, and

institutional HVAC applications It features a zinc plated steel

case, zinc plated steel stem, chrome steel ring, glass win-

dow, and bimetal spiral spring sensing element. Series TBC

thermometers are available in various probe lengths and dual

reading scale (°F, °C).

Features

• Zinc plated steel case
• Glass window
• Zinc plated steel stem
• Chrome steel ring
• Bimetal spiral spring sensing element

Dimensions — Weights

TBC

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

MoDEl

SCAlE

ProbE SizE

DiMEnSionS

WEiGH

A

B

C

D

E

˚F

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

lbs.

kgs.

TBC-2

1

2

-4

32 – 932

0 – 500

4

102

2

1

2

63

4

3

8

111

1

2

13

5

8

16

3

8

9

.5

.23

TBC-2

1

2

-6

32 – 932

0 – 500

6

152

2

1

2

63

6

5

16

160

1

2

13

5

8

16

3

8

9

.5

.23

TBC-2

1

2

-8

32 – 932

0 – 500

8

203

2

1

2

63

8

5

16

211

1

2

13

5

8

16

3

8

9

.5

.23

TBC-2

1

2

-12

32 – 932

0 – 500

12

305

2

1

2

63

12

1

4

311

3

15

16

100

2

15

16

75

3

8

9

.5

.23

Materials

Case:

Zinc plated steel

Window:

Glass

Stem:

Zinc plated steel

Ring:

Chromed steel

Sensing Element: Bimetal spiral spring

Approvals

Certified by The Northern Certification Society of Italy

(Det Norske Verita Italia S.r.l.)

Standards

ISO 9002 quality standard

Temperature

Working Temperature Range: 32°F to 932°F (0°C to 500°C)

ES-TBC 1128

© 2011 Watts

USA: No. Andover, MA • Tel. (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com
Canada: Burlington, ON • Tel. (905) 332-4090 • Fax: (905) 332-7068 • www.wattscanada.ca

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts
reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications
on Watts products previously or subsequently sold.

A Watts Water Technologies Company