RO SYSTEM TROUBLE SHOOTING

PROBLEM REMEDY

General

High Product Water TDS

Membrane frozen, high temp, or backpressure. Replace

membrane.

Membrane attack by chlorine

Carbon pre-filter may be exhausted. Replace filter and membrane.

Product seal on end cap.

Determine if seal or o-ring is bad. Replace as needed.

No Product Water or Not Enough Product Water

Feed water shut off.

Turn on feed water.

Low feed pressure. Feed pressure must be at least 10 psi.

Consider booster pump.

Pre-filter cartridge clogged.

Replace pre-filter cartridge.

Membrane fouled.

Determine and correct cause; replace or clean membrane.

Product check valve stuck.

Clean or replace check valve.

Low pump discharge pressure
Low feed water temperature

Adjust reject valve or replace pump
Increase membrane feed pressure or heat the feed water.



IV.

REPLACEMENT PARTS LIST

A list of common replacement parts is provided below. Contact your dealer for replacement
parts assistance.

Part Number

Description

FPMB5-978 Prefilter

for

R13-0250

FPMB5-20

Prefilter for R13-0600 & R13-1200

R96310

RO membrane for R13-0250

R96320

RO membrane for R13-0600 & R13-1200

PG07B25 Prefilter

pressure gauge 0 – 100 psi

PG20B25

Pump discharge pressure gauge 0 – 300 psi

R5645

Product and reject flow meter 0 – 50 gph

WDM-2 Water

quality

meter

R2200-120/60

Motor 0.5 HP single phase 120 volt

R2101-140

Pump 140 GPH carbonator with relief valve

R23-1070S

Low pressure controller with on/off switch

R23-PS32 Low pressure switch, ¼” MPT
NV-10

Reject & recycle needle valve

R2402

Inlet solenoid valve, 1/2”, 120 volt coil

R9812-4SS

Product check valve

This manual is related to the following products: