Watts R14-03-1WM User Manual
Page 15
![background image](/manuals/589330/15/background.png)
MOTOR TROUBLE SHOOTING CHART
TROUBLE CAUSE
WHAT
TO
DO
Motor fails to start
Blown fuses
Replace fuses with proper type and rating
Overload trips
Check and rest overload in starter.
Improper power supply
Check to see that power supplied agrees with motor
nameplate and load factor.
Open circuit in winding or control switch
Indicated by humming sound when switch is
closed.
Mechanical failure
Check to see if motor and drive turn freely. Check
bearing and lubrication.
Short circuited stator
Indicated by blown fuses. Motor must be rewound.
Poor stator coil connection
Remove end bells, locate with test lamp.
Rotor defective
Look for broken bars or end ring.
Motor may be overloaded
Reduce load.
Motor Stalls
One phase connection
Check lines for open phase.
Wrong application
Change type or size. Consult manufacturer.
Overload motor
Reduce load.
Low motor voltage
See that nameplate voltage is maintained. Check
connection.
Open circuit
Fuses blown, check overload relay, stator and push
buttons.
Motor runs and then dies
down
Power failure
Check for loose connections to line, to fuses and to
control.
Motor does not come up
Not applied properly
Consult supplier for proper type.
to speed
Voltage too low at motor terminals because of line
drop.
Use higher voltage on transformer terminals or
reduce load. Check connections. Check conductors
for proper size.
Broken rotor bars or loose rotor.
Look for cracks near the rings. A new rotor may be
required as repairs are usually temporary.
Motor takes too long to
Open primary circuit
Locate fault with testing device and repair.
accelerate
Excess loading
Reduce load.
Poor circuit
Check for high resistance.
Defective squirrel cage rotor
Replace with new rotor.
Applied voltage too low
Get power company to increase power tap.
Wrong rotation
Wrong sequence of phases
reverse connections at motor or at switchboard.
Motor overheats while
Overloaded
reduce load.
running under load
Frame or bracket vents may be clogged with dirt and
prevent proper ventilation of motor.
Open vent holes and check for a continuous stream
of air from the motor.
Motor may have one phase open
Check to make sure that all leads are well
connected.
Grounded could
Locate and repair.
Unbalanced
terminal
voltage Check
for faulty leads, connections and
transformers.
Motor vibrates after
motor misaligned
Realign
correcting have been
Weak support
Strengthen base.
made
Coupling out of balance
Balance coupling.
Driven equipment unbalanced
Rebalance driven equipment.
Defective ball bearing
Replace bearing.
Bearing not in line
Line properly.
Balancing weights shifted
Rebalance motor.
Polyphase motor running single phase
Check for open circuit.
Excessive end play
Adjust bearing or add washer.