beautypg.com

Watts LF53L User Manual

Calibrated pressure relief valve, Pressure relief valves, Installation guidelines

background image

Limited Warranty: Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of

original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT. THE COMPANY MAKES NO OTHER

WARRANTIES, EXPRESS OR IMPLIED. THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach of warranty, and the Company shall not be responsible for any incidental, special

or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting

from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which the Company has no

control. This warranty shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or alteration of the product.

Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above

limitations may not apply to you. This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State. You should consult applicable state laws to

determine your rights.

SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT.

Installation Guidelines

Model 53 and LF53 Pressure Relief Valves
For pressure relief only. Furnished without a lever.

1

2

" female

drain. Pressure range 75-175psi (5.17-12.06 bar). Setting 50,

75, 125 and 150psi (3.45, 5.17, 8.61 and 10.34 bar).
Series 530C and LF530C

Calibrated Pressure Relief Valves
Calibrated adjustment allows for setting valve to required

pressure relief. Adjustable range 50-175psi (3.45-12.06 bar).

The Series 530C and LF530C is ideal for bypass thermal

expansion pressure relief.
These valves are not an ASME approved safety relief valves

and should not be used in system applications with this

requirement.

Auxiliary (Bleeder) Pressure Relief Valve for

Thermal Expansion Relief

Purpose

Auxiliary (bleeder) pressure relief valve
is set approximately 25psi (172 kPa)
lower than heater T&P valve and
eliminates unnecessary and frequent
relief from hot water heater T&P relief
valve. This protects the system from
thermal expansion pressure buildup
during times when reducing valve thermal

expansion bypass is ineffective due to high inlet water pressure.
The adjustable Series 530C and LF530C is preferred to provide
a range of settings adaptable to any installation. Some national
and regional codes require maximum static (no-flow) pressure at
any fixture to be not more than 80psi (5.5 bar).

Location

Install auxiliary (bleeder) pressure relief valve downstream of
the reducing valve, in any convenient location where slight
spillage is not objectionable. If spillage is frequent, install to
drain in set tubs or other drain location.

IS-53/530C/111

No. 111

No. 530C

No. 53

Installation
Model 530C and LF530C

Calibrated Pressure Relief Valve

Model 53, LF53, 111 and LF111

Pressure Relief Valves

WARNING

!

Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information

can result in death, serious personal injury, property

damage, or damage to the equipment.
Keep this Manual for future reference.

IS-53/530C/111 1325

EDP# 1910868

© 2013 Watts

USA: Tel: (978) 688-1811 • Fax: (978) 794-1848 • www.watts.com
Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • www.watts.ca

A Watts Water Technologies Company

WARNING: This product contains chemicals known

to the State of California to cause cancer and birth

defects or other reproductive harm.

For more information: www.watts.com/prop65

Dielectric Unions

Cold

Water

Heater

Reduced

Pressure

50psi

Cold Supply

Water Pressure

Reducing Valve

Hot

Set Tub

Auxiliary Relief

Valve Can Be

Installed On

Either Hot Or

Cold Piping

*T&P valve should be set according to tank working pressure or local code requirements.
**Only where code approved. NOTE: Resulting system pressure will be as high as bleeder
valve setting (usually 125psi).

**Watts Auxiliary

Thermal Expansion

Pressure Relief Valve

No. 53, LF53, 530C,

LF530C, 111 or LF111

*Watts T&P

Safety Relief

Valve Set At

150psi

One-Way

Flow Device