Installation and Start-up

1. Turn off water heater(s).
2. Turn off the main water supply to the home and open an

inside faucet to relieve any pressure within the plumbing sys-

tem.

3. Place the system in the desired location. Make sure that the

location is level and sturdy enough to support the weight of

the wetted system.

4. Place the bypass valve in the up flow service position. See

below Bypass Valve Modification Detail.

5. Connect the cold water supply to the inlet of the OneFlow

®

system. NOTE: The OneFlow

®

system operates in the

UP-flow mode which is opposite of a conventional softener.

Follow the plumbing diagram in Figure 3.

6. Install a supply valve (user supplied) in the supply line and

close it.

7. Place a bucket under the outlet port or run a line from the

outlet port to a drain.

8. Turn the water back on to the house. Slowly open the sup-

ply valve to the OneFlow

®

system. Allow the tank to fill with

water. Close the supply valve when a steady stream of

water comes out of the outlet port. If the outlet is flowing

into a bucket, water could splash on nearby objects. If this

threatens the safety, value, structure, or appearance of these

objects, protect/remove them or use the outlet hose to drain

option.

9. Close the inside faucet.
10. Connect the outlet of the OneFlow

®

system to the cold

water supply to the house.

11. Open the supply valve to the OneFlow

®

system.

12. Open hot and cold faucets downstream from the OneFlow

®

system to relieve any air from the plumbing system and

water heaters. Then close the faucets.

13. Check for leaks. Repair as needed.
14. The system is now ready for service.

IN

Cold Water

OUT

OneFlow

®

Treated Water

Figure 3.
OFRES shown with bypass as-

sembly.

Service Position

down-flow tank.

As shipped, the bypass is set-up for down-

flow use. The arrow shape of the handles

points in the wrong direction for UP-flow

use. To convert it to UP-flow use, pull up on

the red handles until they come off. Rotate

the handle 180° and put it back on the valve

stem.

Service Position

UP-flow tank.

Bypass Position

UP-flow tank.

Bypass Valve Modification

This manual is related to the following products: