Iron, Manganese and Copper

Just as with conventional water softening media, One-

Flow

®

needs to be protected from excess levels of certain

metals that can easily coat the active surface, reducing

its effectiveness over time. Confirm that the levels of iron

(Fe) and manganese (Mn) are less than 0.3 mg/L and 0.05

mg/L respectively. Copper should be less than .1 ppm.

Copper

Copper usually originates from new copper plumbing

upstream of the OneFlow

®

system. If this condition exists,

we recommend waiting 4 weeks before placing the sys-

tem in operation. This will allow the copper surfaces to be

fully flushed and develop a natural protective surface. To

further minimize any problem with excess copper, avoid

applying excess flux on the inner surfaces of the pipe and

use a low-corrosivity water soluble flux listed under the

ASTM B813 standard. Once the plumbing connections are

complete, place the OneFlow

®

system in bypass prior to

following the startup procedure. All new copper plumbing

before the system should be allowed to passivate for a

period of 4 weeks prior to starting the system up.

!

!

i

Cautions!

• Do not let the system freeze. Damage to the tank may result.
• System must be operated in a vertical position. Do not lay

it down during operation. The system may be placed in any

position for shipping and installation but must be operated in

the vertical position.

• Place the system on a smooth, level surface. Because the

system operates in an UP-Flow, fluidized bed mode, having a

level surface is more important than with a softener or media

filter.

• A bypass valve should be installed on every system to facili-

tate installation and service.

• Observe all local plumbing and building codes when installing

the system.

• Water known to have heavy loads of dirt and debris should

be prefiltered using a 20 micron filter cartridge model number

PWFIL-SED-BB-10-20M-PLT and 1" high flow filter housing

model number PWHSG-ASY-BB-10-1-PR.

• All new copper pipe and fittings used in the installation of this

system should be allowed to self passivate, under normal

operation and water flow, for a period of 4 weeks minimum

before placing the unit into service.

• If making a soldered copper installation, do all sweat soldering

before connecting pipes to the bypass valve. Torch heat will

damage plastic parts.

• When turning threaded pipe fittings onto plastic fittings, use

care not to cross-thread.

• Use PTFE tape on all external pipe threads. Do not use pipe

joint compound.

• Support inlet and outlet plumbing in some manner (use pipe

hangers) to keep the weight off of the bypass fittings.

• Do not use on water that is microbiologically unsafe or of

unknown quality.

Notes to the Installer

The OneFlow

®

system differs from a conventional softener or

media filter in a number of key respects.
• The system is light and only partially filled with media. This is

normal. The UP-flow operation of the system requires a lot of

freeboard to allow the bed to fully fluidize.

• The system has no underbed so you can tip the system over

without any fear of upsetting the media. This makes transpor-

tation and installation much easier than conventional systems.

Must be installed in VERTICAL POSITION.

• Because the OneFlow

®

system operates in the UP-flow

mode, the tank connections are opposite of traditional instal-

lations. Please follow water flow diagram illustrated in Figure

3.

• Please see the “Important note about iron, manganese and

copper in the water supply” section.

• Please see the note about “Using OneFlow

®

with other water

treatment equipment” on the previous page.

• This system is designed for residential applications only.
• This system comes with a bypass valve to bypass the system

in case of a leak or the need to remove the system from the

installation area. The nuts, locking rings, and O-rings must

be installed on the connection fittings by the installer. Please

see Figure 1 Bypass Valve and Connection Fittings detail for

proper assembly of the #CK-V3007. To properly assemble the

connection fitting first install the nut, then install the locking

ring in the grove closest to the nut. Use care not to break the

locking ring. Finally install the O-ring in the grove at the end of

the fitting.

Important Note About Iron, Manganese And Copper

In The Water Supply