beautypg.com

Equipment specifications, Specifications, Ab c mechanical specifications – Watts OFRES-1035 User Manual

Page 3: Using oneflow, With other water treatment equipment, Dimensions

background image

3

Equipment Specifications

Watts OneFlow

®

systems are complete, self-contained, loaded

with media and ready to use. A simple inlet and outlet connec-

tion is all that is required for installation. Please review operat-

ing pressures, temperatures and water chemistry limitations to

ensure compatibility and performance.

Specifications

Chlorine

< 2 ppm

Hardness**

75 grains (1282 ppm CaCo3)

Inlet/Outlet Connection

1" MNPT

Temperature

40° - 110°F (4° - 43°C)

pH

6.5 to 8.5

Ferrous Iron, Max*

0.3 mg/L

Manganese, Max*

0.05 mg/L

Copper, Max*

Less than .1 ppm

Water Pressure (psi)

15psi min., 100psi max

H2S, Oil, Polyphosphate

None allowed

Silica Max

10 ppm

* See note about iron, manganese and copper on the next

page.

** These systems prevent hardness related scale formation inside

the plumbing system of the home at influent hardness levels of

75 grains per gallon of calcium carbonate and less. Due to vari-

ances in water chemistry certain aesthetic conditions external

of the plumbing system may not be attained.

a

b

c

Mechanical Specifications

Model

835

935

1035

Max Service Flow
(gpm)

8

12

16

Dry Weight (lbs)

19

23

25



a

40

40

40

b

37

37

37

c

12

12.5

13

Using OneFlow

®

with other water treatment

equipment.

Due to the unique properties of OneFlow

®

, there are some

unique requirements for using OneFlow

®

in conjunction with filtra-

tion or other forms of water treatment.
1. OneFlow

®

must be the last stage in the treatment chain. Do

not install any filters after OneFlow

®

or before any devices for

which scale prevention is required.

2. Do not apply phosphate or any other antiscalant before or

after OneFlow

®

.

Figure 2.

Note: Peak service flow rate is for intermittent use only and is

not to be interpreted as continuous service flow rate capability.

These systems are designed to treat the domestic water used

in a single family dwelling. For higher volume applications please

contact your Watts representative.

Dimensions

(nominal - inches)

This manual is related to the following products: