beautypg.com

Watts LFN360I User Manual

Lead free, Vacuum relief valves, For water heater/tank applications

background image

Tested and rated under “ANSI Z21.22

Relief Valves for Hot Water Supply Systems”.

Design certified by

LFN360

Model LFN360 and
LFN360I

Vacuum Relief Valves

Sizes:

1

2

" and

3

4

" (15 and 20mm) Male NPT

&

3

4

" MNPT x

3

4

" FNPT

For automatic venting of a closed system to atmosphere when a

vacuum is created. The Watts LFN360 Vacuum Relief Valve permits

air to enter and prevent vacuum conditions that could siphon the

water from the system, resulting in collapse of a tank or water heater

or equipment burn out.

Features

• Low profile
• All Lead Free* brass body
• Can be mounted in a vertical or horizontal position
• Suitable for low pressure steam and water service
• Tested and rated to ANSI Z21.22
• CSA certified

Applications

• Domestic water heaters and supply tanks
• Table top heaters
• Jacketed steam kettles
• Unit heaters
• Low pressure steam systems
• Steam coil heaters
Note: Vacuum relief valves are not designed or approved as back-

siphonage backflow preventers. For protection against back-siphon-

age install Watts Series 288A vacuum breakers.

Specifications

Watts Models LFN360 and LFN360I Vacuum Relief Valves shall be

installed on domestic hot water supply tanks/ heaters/ unit heaters/

steam kettles as indicated on plans. The vacuum relief valve shall be

ANSI Z21.22 rated and CSA certified. The vacuum relief valve shall

have an all Lead Free* brass body with an integral protective cover.

The valve shall be mounted in a vertical or horizontal position. This

device shall be constructed using Lead Free* brass material. Lead

Free* vacuum relief valves shall comply with states codes and stan-

dards where applicable, requiring reduced lead content. The valve

shall be a Watts Model LFN360 and LFN360I.

LFN360I

For Water Heater/Tank Applications

ES-LFN360/LFN360

Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative ––––––––––––––––––––––––––––––––––––––––

LEAD FREE

*

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with-
out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

*The wetted surface of this product contacted by consumable

water contains less than 0.25% of lead by weight.

Pressure — Temperature

Maximum steam working pressure: 15 psi (1.03 bar)
Maximum temperature: 250°F (121°C)

Standards

Tested and rated to ANSI Z21.22
CSA certified

SIZe (DN)

in. mm

Model

Venting CFM

Capacity LPM

1

2

15 N360/N360I

15

425

3

4

20 N360/N360I

15

425

Capacity

This manual is related to the following products: