beautypg.com

Metrohm 894 Professional CVS semiautomated User Manual

Content, Application bulletin 401/1 e

background image

Application Bulletin 401/1 e

Installation instruction for 894 Professional CVS
semiautomated:
894 Professional CVS with 800 Dosinos for automatic dosing

The «894 Professional CVS semiautomated» is a system for

the semiautomatic determination of suppressor in plating

solutions. With the additional accessory kit «Equipment with

2 Dosing Units for VA/CVS» also brightener can be

determined.

PC controlled operation.

Automatic addition of 2 solutions: VMS, suppressor

standard or plating bath sample.

With «Equipment with 2 Dosing Units for VA/CVS»

automatic addition of 4 solutions: VMS, brightener

concentrate, suppressor concentrate and suppressor

standard or plating bath sample.

Applications:

o

Analysis of suppressor concentration in plating

baths with CVS.

o

Analysis of brightener concentration in plating

baths with CVS.

Fig. 1: 894 Professional CVS semiautomated with optional
equipment with 2 Dosing Units for VA/CVS

Content

1.

Instruments and accessories .......................................... 2

2.

System setup .................................................................. 2

2.1.

Electrical connections ............................................ 2

2.2.

Tubing connections for automatic dosing of
standard solutions and auxiliary solutions .............. 3

3.

viva «Configuration» ....................................................... 4

3.1.

Devices .................................................................. 4

3.2.

Sensors/Electrodes ................................................ 4

3.3.

Dosing units ........................................................... 4

3.4.

Solutions ................................................................ 5

4.

viva «Method» ................................................................ 5

4.1.

Method run ............................................................. 5

4.2.

Evaluation .............................................................. 6

5.

Operation........................................................................ 6

5.1.

Suppressor determination ...................................... 6

5.2.

Brightener determination ........................................ 7

6.

Remarks ......................................................................... 7

6.1.

Storing dosing units ............................................... 7

6.2.

Storing electrodes .................................................. 7

6.3.

Waste bottle ........................................................... 7

Page 1 of 7